Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/05/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
05/05/2023 | CDRC Review Coordinator | PENDING ASSIGNMENT | |||
05/05/2023 | Commercial Plumbing | PENDING ASSIGNMENT | |||
05/05/2023 | Fire New Construction | PENDING ASSIGNMENT | |||
05/05/2023 | NPPO | PENDING ASSIGNMENT | |||
05/05/2023 | ROW Engineering Review | PENDING ASSIGNMENT | |||
05/05/2023 | Site Engineering | PENDING ASSIGNMENT | |||
05/05/2023 | Site Landscape | PENDING ASSIGNMENT | |||
05/05/2023 | Site Zoning | PENDING ASSIGNMENT | |||
05/04/2023 | OK to Submit - Landscape | REQUIRES RESUBMIT | PROJECT: SAIA MOTOR FREIGHT TRUCKING FREIGHT FACILITY ACTIVITY NO. TD-DEV-0523-00230 ADDRESS/PARCEL: 7157 S SWAN RD/ 140-39-8760 ZONING: I-1 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TSM) Section for landscape, native plants and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments are addressed. COMMENTS: 1. This plan set is missing the following documents: a. There must be a NPPO. An NPPO is required per UDC 7.7.3-B. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. b. Irrigation plan- Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10. c. A Commercial Rainwater Harvesting Plan – A Commercial Rainwater Harvesting Plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf (See here: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-10684) as well as Ordinance# 10597 (see here: https://www.tucsonaz.gov/files/water/docs/rwhordsum.pdf). Site Water Budget must be included as part of the Rainwater Harvesting Plan (located here: https://www.tucsonaz.gov/pdsd/water-energy-conservation). 2. Include any and all necessary landscape construction details in your submittal, including but not limited to: planting details, irrigation details, and commercial rainwater harvesting details (most can be found here: https://www.tucsonaz.gov/tdot/landscape-architects) 3. Trees must actually shade the parking spaces. Ensure the required number of trees is in all vehicular parking areas (1 tree: 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988 |
||
05/05/2023 | OK to Submit - Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Saia Motore Freight Line, LLC 7157 S. Swan Rd. – I-2 TD-DIV-0523-00230 TRANSMITTAL DATE: May 05, 2023 The development package has been reviewed by the Zoning Review Section for minimal compliance with Administrative Manual (AM) 2-06. It has been determined that the submitted plans do not provide sufficient information to complete a plan review. The following items need to be addressed prior to re-submittal. 1. Provide a Development Package (DP) that meets all requirements of Administrative Manual (AM) 2-06, to include but not limited to: a. All required calculations. b. All required general notes. c. Landscape plans. Review Administrative Manual (AM) 2-06 and provide a complete DP. AM 2-06 can be found at: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-8283. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. |
||
05/04/2023 | CDRC Application Completeness | REVIEW COMPLETED | |||
05/04/2023 | OK to Submit - Engineering | REVIEW COMPLETED |