Permit Number: TD-DEV-0426-00109
Parcel: 10511061A

Address:
4570 N ORACLE RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0426-00109
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2026 Site Zoning Standard APPROVED
05/26/2026 Traffic Engineering Review Standard APPROVED Traffic Engineering has reviewed the provided traffic statement and has no comments.
06/09/2026 NPPO Standard NOT REQUIRED
05/29/2026 External Reviewers - Arizona Department of Transportation (ADOT) Standard REQUIRES RESUBMIT Fwd: TDC External Review PERMIT: TD-DEV-0426-00109Please Sign-In DUE: 6/17/2026
rfreije@azdot.gov
on behalf of
ADOT SC Traffic Engineering - ADOT<adotsctrafficengineering@azdot.gov>

​CDRC​
Because the Sears has been closed for several years, it is not valid to compare the trip generation of the Living Spaces development to the previous trip generation of the Sears. Therefore, the Traffic Impact Analysis (TIA) needs to be revised to treat this as an entirely new development.

The trip generation exceeds the threshold requiring a Category 1 TIA, which means that the intersections of SR 77 (Oracle Road) with Auto Mall Drive, Wetmore Road, and the full access driveway in between should all be evaluated for the opening year and a horizon year (3 years after the opening year).

Thanks, Rick Freije
05/21/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0426-00109 (1st Review)
Project: Minor Development Package for the addition of a concrete loading area to the existing Living Spaces facility.
Location: 4570 N ORACLE RD
Review Date: 5/21/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases: TP-PRE-0226-00052
*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0426-00109, adjacent to the title block on all sheets
2. Provide radii’ measurements to the Overall Vehicle Tracking sheet (Sheet 4).
3. Provide a surfacing construction detail to demonstrate compliance with UDC 7.4.6.I regarding surfacing requirements.
4. The plans show call out for a retaining wall to the Northeast & Northwest corners of the existing building. It will be required that a separate wall building permit be submitted for the construction of the walls. For the wall permits, please submit the structural calculations and drawings for the construction of the wall. Revise all the associated Site keynotes to: “Wall to be built under separate permit.”
5. Provide a construction profile/detail for the pump discharge and drain inlet leading to the landscaped area. Ensure to include proper intended elevations with inverts.
6. Add dimensions to the PAAL/Vehicle Use Area.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
06/09/2026 Site Landscape Standard REQUIRES RESUBMIT PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, PLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: MINOR DEVELOPMENT PACKAGE FOR THE ADDITION OF A CONCRETE LOADING AREA TO THE EXISTING LIVING SPACES FACILITY
ACTIVITY NO: TD-DEV-0426-00109
ADDRESS: 4570 N ORACLE RD
ZONING: COMMERCIAL ZONE (C-3)
6.9.2026

THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM).

RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. A tree appears to be within the demolition area. Show a 1:1 ratio replacement for the tree at a 15-gallon size somewhere else on site. The tree symbol, plant key with scientific name and common name, tree planting detail and tap into existing irrigation system can be shown on this minor development package site plan.

Thank you.
Chad Keller, PLA
Landscape Architect
chad.keller@tucsonaz.gov
05/19/2026 CDRC Application Completeness Express REVIEW COMPLETED
05/19/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added Addressing, ADOT, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing, ADOT, and TEP. FYI email sent to PAG, USPS, SWG.
06/09/2026 Commercial Plumbing Standard REVIEW COMPLETED
05/19/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
05/19/2026 External Reviewers - Pima County Addressing Standard REVIEW COMPLETED Good afternoon,

TD-DEV-0426-00109 does not require review from Pima County Addressing.


Thank you,







David Wilging

Planner I - Addressing Division

Pima County Development Services

201 N. Stone Avenue 1st Floor

Tucson, Arizona 85701

520-724-6381
05/19/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
06/03/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED June 2, 2026
WO#T184799
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: Living Spaces - Tucson Mall
TD-DEV-0426-00109
Tucson Electric Power Company (TEP) has reviewed and approved the development
plan submitted 5/19/2026. There are no existing facilities within the development. There
are no apparent conflicts at this time.
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
Questions regarding Land, ROW, Easement, etc., please contact the TEP Land
Department
Liz Boehler
Right of Way Agent
Consultant
520-686-1341
Landreviews@tep.com
Should you have any technical questions, please contact the area designer,
Chuck Leon
(520) 400-6133
cleon@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
05/19/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
06/06/2026 Fire New Construction Standard REVIEW COMPLETED
05/19/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
06/10/2026 ROW Engineering Review Standard REVIEW COMPLETED