Permit Number - TD-DEV-0426-00104
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 05/15/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0426-00104 – Minor DP – Parking Area and Drive Thru Modifications Location: 9410 E GOLF LINKS RD Review Date: 5/15/2026 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage… Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete… Overall for application submittal requirements, see Administrative Manual Section 2-06 Site Engineering: 1. Provide the development package case number, TD-DEV-0426-00104, adjacent to the title block on all sheets Pedestrian Circulation and Vehicle Use Area Comments: 1. Sheet 5 Keynote 4 calls out PAG SD 210 at the proposed location of the ADA parking stall, which would cut off ADA accessibility to the existing path on the west of the building. This is also called out on Sheet 7 as PAG SD 213. Please revise the plans to provide access to the parking stall. 2. Plans show the removal of one parking space from 26 to 25. Please provide additional ADA parking stall as required per 2010 ADA Standards for Accessible Design. If the intent is to use the ADA accessible parking space to the south shown as remaining on Sheet 4, that space is for access to adjacent lot business, and not included in the original 26 space count. 3. Please provide ADA accessible ramp access and signing for both required ADA parking spaces. See above comment #2. Drainage comments: 1. This site lies within a COT floodplain associated with the Rolling Hills Wash. In compliance with COT Floodplain requirements, a floodplain use permit (FPU) will be required for submittal with this proposed development project. If you have any questions or concerns, please contact: Joe Macaulay at Joe.Macaulay@tucsonaz.gov |
||
| 04/29/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added TEP, PAG, USPS, and SWG to the workflow. Review request email sent to TEP. FYI email sent to PAG, USPS, SWG. | ||
| 05/19/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 04/29/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/29/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 05/13/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | May 13, 2026 WO#T183157 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Whataburger - Golf Links and Harrison TD-DEV-0426-00104 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 4/29/2026. There are existing facilities within the development which are depicted upon the plan. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. Questions regarding Land, ROW, Easement, etc., please contact the TEP Land Department Liz Boehler Right of Way Agent Consultant 520-686-1341 Landreviews@tep.com Should you have any technical questions, please contact the area designer, Martin Rodriguez (520) 991-5495 mrodriguez@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 04/29/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/28/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 05/14/2026 | ROW Engineering Review Standard | REVIEW COMPLETED |