Permit Number: TD-DEV-0426-00104
Parcel: 13613001W

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0426-00104
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Fire New Construction Standard PENDING ASSIGNMENT
N/A NPPO Standard PENDING ASSIGNMENT
N/A Site Landscape Standard PENDING ASSIGNMENT
N/A Site Zoning Standard PENDING ASSIGNMENT
05/15/2026 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-0426-00104 – Minor DP – Parking Area and Drive Thru Modifications
Location: 9410 E GOLF LINKS RD
Review Date: 5/15/2026

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.

Drainage Manual Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage…

Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-rete…

Overall for application submittal requirements, see Administrative Manual Section 2-06

Site Engineering:
1. Provide the development package case number, TD-DEV-0426-00104, adjacent to the title block on all sheets
Pedestrian Circulation and Vehicle Use Area Comments:
1. Sheet 5 Keynote 4 calls out PAG SD 210 at the proposed location of the ADA parking stall, which would cut off ADA accessibility to the existing path on the west of the building. This is also called out on Sheet 7 as PAG SD 213. Please revise the plans to provide access to the parking stall.
2. Plans show the removal of one parking space from 26 to 25. Please provide additional ADA parking stall as required per 2010 ADA Standards for Accessible Design. If the intent is to use the ADA accessible parking space to the south shown as remaining on Sheet 4, that space is for access to adjacent lot business, and not included in the original 26 space count.
3. Please provide ADA accessible ramp access and signing for both required ADA parking spaces. See above comment #2.
Drainage comments:
1. This site lies within a COT floodplain associated with the Rolling Hills Wash. In compliance with COT Floodplain requirements, a floodplain use permit (FPU) will be required for submittal with this proposed development project.

If you have any questions or concerns, please contact: Joe Macaulay at Joe.Macaulay@tucsonaz.gov
04/29/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TEP, PAG, USPS, and SWG to the workflow. Review request email sent to TEP.  FYI email sent to PAG, USPS, SWG.
05/19/2026 Commercial Plumbing Standard REVIEW COMPLETED
04/29/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/29/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
05/13/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED May 13, 2026
WO#T183157
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: Whataburger - Golf Links and Harrison
TD-DEV-0426-00104
Tucson Electric Power Company (TEP) has reviewed and approved the development
plan submitted 4/29/2026. There are existing facilities within the development which are
depicted upon the plan.
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
Questions regarding Land, ROW, Easement, etc., please contact the TEP Land
Department
Liz Boehler
Right of Way Agent
Consultant
520-686-1341
Landreviews@tep.com
Should you have any technical questions, please contact the area designer,
Martin Rodriguez
(520) 991-5495
mrodriguez@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
04/29/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/28/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
05/14/2026 ROW Engineering Review Standard REVIEW COMPLETED