Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0426-00102
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| N/A | External Reviewers - Tucson Electric Power (TEP) Standard | PENDING ASSIGNMENT | |||
| N/A | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| N/A | NPPO Standard | PENDING ASSIGNMENT | |||
| N/A | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| N/A | Site Landscape Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 04/28/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0426-00102 (1st Review) Project: New commercial Valvoline building Location: 5437 E 22ND ST Review Date: 4/28/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Related Cases: TP-PRE-0126-00002 *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Provide the development package case number, TD-DEV-0426-00102, adjacent to the title block on all sheets 2. Revise the general note #16 to be updated to current adopted codes : Accessible standards must be met per 2024 IBC, chapter 11, and 2017 ICC A117.1 3. Delineate/show the angle of the parking spaces for the northern portion of the site on the site plan (Sheet 4) 4. Include spot elevations at curb cut inlets and curb cut outlets for quick reference during site inspections. 5. Per TSM 7-01.4.1.B – a sidewalk will be required on the northern side of the proposed new building. 6. Per TSM 7-01.4.E and TSM 7-01.4.3.E – it will be necessary that the downspout shown on the East side of the building be moved as it would directly discharge across the pedestrian route. 7. After review of detail E on sheet 7, it appears it does not meet the minimum standards as established in TSM 8-01.5.0 a. If deviations are desired from the standard single enclosures, then Environmental services approval will be required. The contact to reach out to at ES will be Andy Vera at Andy.vera@tucsonaz.gov. Please submit the approval provided for the resubmission of this development package. If approval is provided, a Technical Standards Modification Request (TSMR) should be included in the resubmission. 8. As this Valvoline is being proposed apart of a greater size commercial property, all the buildings fall within the same site. In compliance with TSM 7-01.3.3, provide a pedestrian connection to connect to the site’s overall connectivity. This means connecting to the northern connection. If this is determined to be difficult/unachievable, a TSMR would be suggested with sufficient justification/reasoning as to why a pathway cannot be established. 9. As the work proposed in the north parking area appears to fall within the City of Tucson Alamo Wash floodplain study area, it will be required that a floodplain use (FPU) permit be submitted for review/approval. This is an entirely separate permit that can be submitted for within the sub-records of this development package permit. For the FPU permit submission, as this simply falls into “Work within a floodplain” – all that will be required is the associated plan set for submission. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/20/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 04/24/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing and TEP. FYI email sent to PAG, USPS, SWG. | ||
| 04/24/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/27/2026 | External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | CDRC Good afternoon, Pima County Addressing approves of TD-DEV-0426-00102. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
||
| 04/24/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/24/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/20/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 04/24/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 04/24/2026 | ROW Review | REVIEW COMPLETED |