Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0426-00087
Parcel: 14026040C

Address:
2850 E DREXEL RD

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0426-00087
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Commercial Plumbing Standard PENDING ASSIGNMENT
N/A External Reviewers - Tucson Airport Authority Standard PENDING ASSIGNMENT
N/A External Reviewers - Tucson Electric Power (TEP) Standard PENDING ASSIGNMENT
N/A Fire New Construction Standard PENDING ASSIGNMENT
N/A NPPO Standard PENDING ASSIGNMENT
N/A ROW Engineering Review Standard PENDING ASSIGNMENT
N/A Site Landscape Standard PENDING ASSIGNMENT
N/A Site Zoning Standard PENDING ASSIGNMENT
04/15/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0426-00087 (1st Review)
Project: Development Package for the expansion of an existing site at Dock-Hi Industrial
Location: 2850 E DREXEL RD
Review Date: 4/15/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases: DP16-0184 (Grading/Drainage)

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0426-00087 adjacent to the title block on all sheets
2. Based on the waste stream calculations provided on the cover sheet – demonstrate how the additional waste generated will be realistically managed. To allow for the continuation of the existing service and potential additional pick-up service – Environmental Services approval will be required - The contact to reach out to at ES will be Andy Vera at Andy.vera@tucsonaz.gov. Please submit the approval provided for the resubmission of this development package. If it is decided that a new enclosure is necessary – provide trash enclosure construction details in compliance with TSM 8-01.5.0 It’s encouraged to use the figures presented in TSM 8-01.9.0 for minimum basis for details for the Dumpster layout shown.
3. Provide a construction detail(s) relating to the gate and fence as referenced by Keynotes #8 & 9 on sheet 3. If they are existing – including existing within the keynote.
4. Provide a construction detail(s) relating to the referenced concrete splash block Keynote #8 – Will this be a pre-cast loose splash block or imbedded pavement? This is due to the geotechnical report stating that loose blocks should not be used.
5. Revise/update the notes under “WORK TO BE DONE” on sheet 4 – Standard specifications for public improvements should be “PAG standard specifications and details for public improvements (2015 Edition) Pima County and City of Tucson”
a. #2 Pavement Marking Design Manual & #3 Traffic Signing Design Manual should be – “Pima County/City of Tucson Signing and Pavement Marking Manual (2020)” – The two previously separate manuals have effectively been merged into one.
b. It appears the correct editions/manuals are referenced on sheet 2
6. It appears notes #11-13 under Paving notes (sheet 2) are duplicated – revise accordingly.

Drainage Statement Comments:
7. Revise the drainage document to provide sufficient references within the Appendix showing that the drainage improvements initially completed under DP16-0184 completely factored in the construction of this proposed expansion.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/07/2026 CDRC Application Completeness Express REVIEW COMPLETED
04/10/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TAA, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to TAA and TEP. FYI email sent to PAG, USPS, SWG.
04/10/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/10/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/10/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/08/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
04/10/2026 OK to Submit - Zoning Fast REVIEW COMPLETED