Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0425-00123
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. Address all zoning comments. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 07/31/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Friendly Village – Covered Parking Structures w/Solar Development Package (2nd Review) TD-DEV-0425-00123 TRANSMITTAL DATE: July 31, 2025 DUE DATE: August 4, 2025 This comment was not fully addressed. All comments shall have a response. COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Per UDC Article 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is April 27, 2026. 2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS 1. COMMENT: 2-06.2.2 – As this development package has not yet been approved remove all revision clouds and deltas from the plan. 2-06.4.0 CONTENT REQUIREMENTS 2. This comment was not addressed. COMMENT: 2-06.4.2.B – Provide a brief legal description within the title block. 3. This comment was not addressed. COMMENT: 2-06.4.4.C – Provide the section, township, and range and label the section corners; north arrow; and the scale on the project-location map 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 4. This comment was not addressed. COMMENT: 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. 5. COMMENT: 2-06.4.9.O – Per UDC Article 6.3.3.B a mobile home park is considered a nonresidential use. Per UDC Table 6.3-2.A Nonres Use to Res Zone the required perimeter yard setback is 10’ or ¾ H (Height of the exterior wall. Based on a wall height of 17’-4” the required perimeter yard setback from array 6 to the north property line is 13’-0”. Per UDC Article 6.4.5.B.2 A vertical structural member(s) (i.e., post, column, dormer wall) supporting a roof extension from the principal structure is considered a wall for applying perimeter yard requirements. Based on Section 3 sheet 5 you are proposing an 8’-0” perimeter yard setback from array 6 to the north property line. A Design Development Option (DDO) will need to be submitted and approved for the reduced setback. 6. COMMENT: 2-06.4.9.O – The “8’-0” BUILDING SETBACK LINE” shown along the east and west property lines and the “6’-0” BUILDING SETBACK LINE” shown along the north property line are not correct. Per UDC Article 6.3.3.B a mobile home park is considered a nonresidential use. Per UDC Table 6.3-2.A Nonres Use to Res Zone the required perimeter yard setback is 10’ or ¾ H (Height of the exterior wall. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 08/12/2025 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | 4350 E. Irvington Road Post Office Box 711, Tucson, AZ 85702 August 12, 2025 WO#T150192 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Friendly Village TD-DEV-0425-00123 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 4/28/2025. There are existing facilities within the development, which are depicted upon the plan. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Chuck Leon (520) 400-6133 cleon@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |