Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0425-00110
Parcel: 12705147A

Address:
910 N SWAN RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0425-00110
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/12/2025 Commercial Plumbing Standard APPROVED
05/12/2025 Site Zoning Standard APPROVED
05/09/2025 NPPO Standard NOT REQUIRED
05/16/2025 External Reviewers - Tucson Electric Power (TEP) Standard REQUIRES RESUBMIT May 16, 2025
WO#T149029
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: Twice the Ice
TD-DEV-0425-00110
Tucson Electric Power Company (TEP) has reviewed and cannot approve the
development plan submitted 4/17/2025. There are existing facilities within the
development, which are not depicted upon the plan. Possible conflicts with overhead
service line. Please contact design if relocation is required.
Enclosed is a copy of a TEP facilities map showing the approximate location of the
existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-
8300. Please submit a final set of plans including approved site, electric load, paving
off-site improvements and irrigation plans. If available, include a PDF version of the
plans.
If easements are required, they will be secured by separate instrument. Should you
have any easement questions, please contact our Land Resources Department,
LandReviews@tep.com.
Should you have any technical questions, please contact the area designer,
Martin Salazar
(520) 305-6713
msalazar@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
04/21/2025 ROW Engineering Review Standard REQUIRES RESUBMIT TD-DEV-0425-00110 • 910 N SWAN RD

1. Per Sec. 25-43 of the Tucson City Code, the southern curb opening on Swan Rd will have to be closed.

2. Provide a general note indicating that any work within the public rights-of-way will require a Right-of-Way Permit from COT Department of Transportation and Mobility.

If you have any questions, please contact Richard Leigh at Richard Leigh at richard.leigh@tucsonaz.gov
05/12/2025 Site Engineering Standard REQUIRES RESUBMIT TD-DEV-0425-00110
910 N SWAN RD

Site engineering comments are as follows:
1. The southernmost parking stall does not have proper vertical separation for the back up spur. Vertical separation between the PAAL and pedestrian use area is required, along with 3ft of clear vehicle overhang. See UDC Art 7.4.6.4 vehicle use criteria.
2. The pedestrian circulation at the back up spur location is reduced to less than 4 feet. See TSM Sec 7-01.9.0 for vertical separation of pedestrian use areas.
Ryan Insalaco – ryan.insalaco@tucsonaz.gov
05/13/2025 Site Landscape Standard REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: DP FOR NEW ICE KIOSK
ACTIVITY NO: TD-DEV-0425-00110
ADDRESS: 910 N SWAN RD
ZONING: C-1 COMMERCIAL ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. For the updated parking area please add one shade tree to meet the standard of 1 tree to every 4 parking spaces. Select a shade tree from the ADWR drought tolerant plant list and include a detail for a tree planting. If an example detail is needed, then please reach out and I will email one to you. Below is a link to the ADWR drought tolerant plant list for your reference: https://www.azwater.gov/sites/default/files/media/5MPTucsonLWUPL_Final.pdf

2. Currently the planter island that is provided for the tree at the south end of the parking area is only 3’ wide. The minimum width is 4’ per City of Tucson code. Adjust this width for tree health with the next submittal.

3. Include a construction detail showing root barriers for trees located near hardscape areas. See Detail 402 located here: https://www.tucsonaz.gov/Departments/Transportation-Mobility/Landscape/Landscape-Architects

4. Include a drip irrigation plan and applicable details for the tree planting.

5. Depress the tree planting area 4” to 6” for rainwater harvesting. If feasible grade the new parking area and new sidewalk towards the depressed tree planting area and provide a curb cut inlet on the parking area side.

6. Specify inorganic ground cover for the depressed planting area. Example: 2” depth of 1” screened rock.

7. Provide the development package case number, TD-DEV-0425-00110, adjacent to the title block on all landscape sheets. Administrative Manual 2-06.4.3

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
04/11/2025 CDRC Application Completeness Express REVIEW COMPLETED
04/17/2025 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TEP to the workflow. Review request email sent to TEP.
05/05/2025 Fire New Construction Standard REVIEW COMPLETED
04/17/2025 OK to Submit - Engineering Fast REVIEW COMPLETED
04/16/2025 OK to Submit - Zoning Fast REVIEW COMPLETED