Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0423-00205
Parcel: 141113720

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0423-00205
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/20/2023 NPPO APPROVED
07/07/2023 Site Engineering APPROVED
06/20/2023 Site Landscape APPROVED
06/30/2023 Site Zoning APPROVED
07/19/2023 CDRC Post Review Express PENDING ASSIGNMENT
07/19/2023 Commercial Plumbing REQUIRES RESUBMIT Comment not resolved. The maximum horizontal length between cleanouts, in this case, cannot be greater than 96.1’, not 100 feet. [Initial comment: The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length from the upstream entrance of the cleanout. With a cleanout rim elevation of 24.4’ and an invert of 20.5’, the maximum horizontal length between cleanouts is 96.1’. Reference: Section 708.1.1, IPC 2018.]
07/17/2023 Traffic Engineering Review REQUIRES RESUBMIT TD-DEV-0223-00205
8205 S. Camino De Café

Comments:
1. Entrance tie-in to ROW must have a P.A.G. standard 206 Concrete Driveway Apron.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
06/20/2023 CDRC Application Completeness Express REVIEW COMPLETED