| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/17/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REQUIRES RESUBMIT | April 17, 2026 WO#T180488 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: FLOWERS AND BULLETS EXPANSION TD-DEV-0326-00073 Tucson Electric Power Company (TEP) has reviewed and cannot approve the development plan submitted 3/26/2026. There are no existing facilities within the development.No apparent conflicts Further: TEP existing faclities and existing easement Docket-8335 at Page-898 must be shown on the Development Plan. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918-8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Fred Quintero (520) 235-6329 fquintero@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 04/17/2026 | NPPO Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: NEW 1,738 SF KITCHEN BUILDING ACTIVITY NO: TD-DEV-0326-00073 ADDRESS: 3538 E ELLINGTON PL ZONING: RESIDENCE ZONE (R-1) 2026.04.17 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM). RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. The proposed work appears to be avoiding the existing trees on site. Please provide a NPPO Waiver for the trees in the area of the proposed work. This is for record keeping purposes within the project file. Thank you. Chad Keller, PLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 03/31/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0326-00073 (1st Review) Project: New 1,738 SF kitchen building Location: 3538 E ELLINGTON PL Review Date: 3/31/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering Related Cases: *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Provide the development package case number, TD-DEV-0326-00073, adjacent to the title block on all sheets 2. Demonstrate how the proposed new pathway falls in compliance with TSM 7-01.4.3 regarding the composition of said pathway. DG will not be accepted as the accessible pathway per TSM 7-01.4.3.C.6 If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 04/17/2026 | Site Landscape Standard | REQUIRES RESUBMIT | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: NEW 1,738 SF KITCHEN BUILDING ACTIVITY NO: TD-DEV-0326-00073 ADDRESS: 3538 E ELLINGTON PL ZONING: RESIDENCE ZONE (R-1) 2026.04.17 THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM). RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. At the new building and associated sidewalk, revegetate and provide screened rock where the construction/grading limits may leave bare exposed soil. Add a few trees for additional shade and supplemental irrigation for plant establishment. Thank you. Chad Keller, PLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 04/15/2026 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: Flowers and Bullets Expansion – 3538 E. Ellington Place Tucson, AZ 85713 Development Package (1st Review) TD-DEV-0326-00073 TRANSMITTAL DATE: 4/15/2026 DUE DATE: 4/17/2026 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is March 25, 2027. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) CONTENT REQUIREMENTS 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 1. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-0326-00073, adjacent to the title block on each sheet. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 2-06.4.7.A.4 - Identify the existing and proposed use of the property as classified per the UDC. List all UDC sections applicable to the proposed uses. 2. COMMENT: 2-06.4.7.A.4 – Please apply for a Zoning Compliance letter to demonstrate the proposed use is permitted. It is unclear if the proposed kitchen is a second principal use or if the kitchen is an accessory use to the Crop Production use. Zoning cannot identify a use permitted in the R-1 zone that would allow the kitchen as a second principal use; however, if the applicant can demonstrate the proposed kitchen is an accessory use to the principal use, Crop Production, the use may be permitted. Per UDC 11.4.2 an accessory use is subordinate to the principal use on a lot serving a purpose customarily incidental to the use of the principal use. Also, please include the associated Use Specific Standards as noted by the standard above. Per UDC Table 4.8-2, Crop Production has 4.9.2.C as the only Use Specific Standard. 2-06.4.7.A.8.a - Floor area for each building; 3. COMMENT: 2-06.4.7.A.8.a – As this site falls within the Davis Monthan Air Force Base overlay ADC-1 (UDC 5.6.A.1), demonstrate you meet the requirements of the maximum FAR .50 of the project area. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 4. COMMENT: 2-06.4.9.F – The zoning classification listed to the West of the parcel is incorrect. It should be labeled as R-1 not C-1 as shown on sheet 1 or R-2 as shown on sheet 2. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 5. COMMENT: 2-06.4.9.R – Please address Site Engineering comments as it relates to DG in the pedestrian pathway. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations *** If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 03/20/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 03/26/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing, TAA, ADOT, TEP, PAG, USPS, and SWG to the workflow. Review request email sent to Addressing, TAA, ADOT, and TEP. FYI email sent to PAG, USPS, SWG. | ||
| 04/14/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 04/16/2026 | External Reviewers - Arizona Department of Transportation (ADOT) Standard | REVIEW COMPLETED | CDRC ADOT has no comments. Thanks, Rick Freije |
||
| 03/26/2026 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 05/04/2026 | External Reviewers - Pima County Addressing Standard | REVIEW COMPLETED | Good morning, Pima County Addressing approves TD-DEV-0326-00073. Thank you, David Wilging Planner I - Addressing Division Pima County Development Services 201 N. Stone Avenue 1st Floor Tucson, Arizona 85701 520-724-6381 |
||
| 03/26/2026 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/16/2026 | External Reviewers - Tucson Airport Authority Standard | REVIEW COMPLETED | April 14, 2026 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0326-00073, 1st Submittal, Flowers and Bullets Expansion / 3538 E Ellington Pl, Tucson, AZ. 85713, Received March 26, 2026 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0326-00073, 1st Submittal, a development plan for a new kitchen building at 3538 E Ellington Pl. This development is located in the N.E. quarter of the S.E. quarter of Section 21, Township 14S, Range 14E, of the Gila and Salt River Meridian. The development site occupies parcel number 130-06-004A, covers approximately 9.65 ± acres, and is zoned as Residence 1 Zone (R-1). The nearest major roadway intersection is South Palo Verde Avenue and East Ellington Place, approximately 50 feet to the northwest of the subject development. This site does lie within FAA Part 77 airspace. The Tucson Airport Authority does not object to this submittal and does not have any additional comments to provide. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning cc file |
||
| 03/26/2026 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/17/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 03/23/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 03/25/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 04/22/2026 | ROW Engineering Review Standard | REVIEW COMPLETED | |||
| 04/02/2026 | ROW Review | REVIEW COMPLETED |