Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0326-00068
Parcel: 11105016B

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0326-00068
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/23/2026 Site Landscape Standard APPROVED
04/23/2026 NPPO Standard NOT REQUIRED
04/24/2026 Fire New Construction Standard REQUIRES RESUBMIT -knox electric key switches are required on electric gates for fire dept. access. knox key boxes are required if non-powered gates are installed. Include appropriate notes on drawings on which knox devices will be installed/added.
john.vincent@tucsonaz.gov
5203495581
04/22/2026 ROW Engineering Review Standard REQUIRES RESUBMIT Looks like gate has already been constructed,
Gated entrances are allowed for apartments where on-site parking areas are privately maintained. Gated entries shall meet the following requirements:
• Stopping locations for keypads, card-readers, guard shacks, etc. shall be set back from the right-of-way of the cross street to avoid interfering with through traffic and to provide protection for entering vehicles.
• The gate may not encroach into the travel lane when open.
• Each side of a median-divided roadway/driveway shall be at least 16 feet wide to provide accessibility of emergency vehicles.
• Any equipment or obstructions such as keypads or card-readers shall be installed in a median island.
• The design of the entrance shall allow vehicles that do not go past the gate to turn around without interfering with other traffic.
• The turnaround area shall be located within the development boundary outside of the collector or arterial right-of-way.
04/06/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0326-00068 (1st Review)
Project: New gates at the property entrances and a portion of new metal fencing adjacent to the gates + Shipping container
Location: 3125 N ALVERNON WY
Review Date: 4/6/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases: TC-COM-0226-00215 (Gate/Fence) & TC-FBB-0226-00182 (Container)

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0326-00068, adjacent to the title block on all sheets.
2. Provide the Zoning and Land Use General note: “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” AM 2-06.4.7.B.1
3. Provide the Zoning and Land Use General Note: “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” AM 2-06.4.7.B.3
4. Provide the Zoning and Land Use General Note: “Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public.” AM 2-06.4.7.D
5. Provide the Zoning and Land Use General Note: “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2
6. Revise the sheet index to reflect all development package pages/sheets.
a. This should be done for the bottom corner sheet xx of xx. This would mean the total page count should be XX of 12 based on what the current DP file shows
7. Update the site expansion and lot coverage calculations to include the full scope of the shipping container referenced.
8. Revise the plan set to provide Sight visibility triangles for all site entrance in compliance with TSM 10-01.5.0. NOTE: Alvernon WY & Presidio RD, Alvernon is designated as an Arterial RD and Presidio RD is designated as a minor/local road. These designations will be used for Table 5.3. Refer to TSM 10-01.9.0 Figures 16-18 for examples of SVTs.
9. For the entrance along Alvernon WY, because it is designated as an Arterial Road, show vehicle maneuverability to demonstrate how a vehicle who attempts to use the closed/gated off entrance can turn around onsite without having to back up into Alvernon WY ROW. City of Tucson 5.11 Access Management Guidelines

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/20/2026 Site Zoning Standard REQUIRES RESUBMIT 1. COMMENT: Per UDC Table 6.3-2.A, the minimum setback for the proposed shipping container is 10' or 3/4 the height of the structure, whichever is greater. The container must be moved, or otherwise, neighbor waiver may be obtained from all adjacent property owners allowing it to remain within the setback. Neighbor waiver language, if signed, should be placed on the next site plan submittal:

My Name is __________________ and I am the owner of the property located at
________________________.
I have reviewed the site plan and I have no objection to structure being located or
constructed ______ feet from the property line as depicted on the site plan.
Signature: _____________________________ Date:_________________________________

If the waiver cannot be obtainer, then a Design Development Option (DDO) may be requested to reduce the minimum setback distance.

2. COMMENT: Indicate the dimensions of the shipping container and it's height.

3. COMMENT: Correct and provide a general note on the cover sheet indicating what percent expansion the shipping container represents as part of the existing gross floor area on the site. The shipping container will count as an expansion.

4. COMMENT: Remove sheets G1.02, G1.03, A2.01, A2.02, A3.01, A3.02, and A3.05.

Contact Fernando Garcia, Lead Planner, Site Zoning at fernando.garcia2@tucsonaz.gov.
04/03/2026 CDRC Review Coordinator Express REVIEW COMPLETED NO EXTERNAL REVIEWERS
External Reviewers not required. No further action is required from the customer at this time.
04/20/2026 Commercial Plumbing Standard REVIEW COMPLETED
04/02/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
04/08/2026 ROW Review REVIEW COMPLETED