Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0326-00064
Parcel: 305230070

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0326-00064
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/13/2026 Site Landscape Standard APPROVED
05/13/2026 NPPO Standard NOT REQUIRED
05/12/2026 Site Zoning Standard NOT REQUIRED Property is located outside City of Tucson jurisdiction. Site Zoning review not required.
04/22/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0326-00064 (1st Review)
Project: TW Storage and Pumping Facility
Location: 15900 S HOUGHTON RD
Review Date: 4/22/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0326-00064, adjacent to the title block on all sheets
2. Provide the Zoning and Land Use General note: “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” AM 2-06.4.7.B.1
3. Provide the Zoning and Land Use General Note: “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” AM 2-06.4.7.B.3
4. Provide the Zoning and Land Use General Note: “Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public.” AM 2-06.4.7.D
5. Provide the Zoning and Land Use General Note: “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2
6. As the perimeter wall proposed for site is shown to be 8-feet tall CMU, it will be required that a separate wall building permit be submitted for structural review. All non-retaining walls that exceed 7-feet in height from natural grade fall under the “structural” designation. For the new wall permit, please submit the structural calculations and drawings for the construction of the wall. Revise the keynote for the wall to reflect this: “Wall to be built under separate permit.”
7. On the proposed civil site plan (Sheet C-103), provide dimensions for the linear foot print of the new block wall.
a. Also dimension the proposed driveway/entrance proposed.
b. These dimensions should be demonstrated on the grading plan sheets as well.
8. Provide the new building square footage and height on the overall civil site plan (C-103)

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/20/2026 CDRC Application Completeness Express REVIEW COMPLETED
04/20/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TEP, PAG, USPS, and SWG to the workflow. Review request email sent to TEP. FYI email sent to PAG, USPS, SWG.
05/08/2026 Commercial Plumbing Standard REVIEW COMPLETED
04/20/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/20/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
05/07/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED TRICO REVIEW- Please see the email forwarded with the TRICOS link to continue. Thanks
04/20/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
05/12/2026 Fire New Construction Standard REVIEW COMPLETED
04/20/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
05/14/2026 ROW Engineering Review Standard REVIEW COMPLETED Project is in Pima County Jurisdiction. Contact Pima County Development services and PC DOT for review