Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - TD-DEV-0325-00070
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | |||
| 05/20/2026 | Design Review Standard | REQUIRES RESUBMIT | |||
| 05/20/2026 | External Reviewers - Tucson Electric Power (TEP) Standard | REQUIRES RESUBMIT | |||
| 05/20/2026 | ROW Engineering Review Standard | REQUIRES RESUBMIT | |||
| 05/15/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0325-00070 (REV 1 – 1st Review) Project: Rev 1 - update to parking, grading, slope, irrigation, utilities, started 05.08.2026 ** New 3-story multi-family residential building Location: 115 S LINDA AV Review Date: 5/15/2026 Due: 5/28/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Provide a geotechnical statement from the geotechnical engineer certifying that the proposed Swale to the West of the structure would be advisable & compliant with overall geotechnical analysis. The report describes that positive drainage should be maintained at least 10-ft beyond the perimeter of the building. Per the Drainage Manual 7.6.5 – buildings are to be setback 10-feet from drainage swales. It may be determined that the swale may need to be grouted to prevent Signiant infiltration near the building foundation. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 05/20/2026 | Site Landscape Standard | REQUIRES RESUBMIT | |||
| 05/20/2026 | Site Zoning Standard | REQUIRES RESUBMIT | |||
| 05/08/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 05/13/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added TEP to review. Email sent to TEP for review. | ||
| 05/08/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 05/12/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |