Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.4
Permit Number - TD-DEV-0323-00166
Review Name: DEVELOPMENT PACKAGE NEW v.4
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/11/2025 | Commercial Plumbing | REQUIRES RESUBMIT | ACTIVITY NO. TD-DEV-0323-00166 ADDRESS/PARCEL: 1635 N BELVEDERE AV TUCSON, AZ 85712 The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: Backwater Valve Required 1. The upstream manhole, #8549-01, has a rim elevation of 2475.83. The proposed fourplex has a FFE of 2475.52. If FFE is not at least 12 inches higher than the nearest upstream manhole, a backwater valve for the sewer line is required. Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. |