Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0323-00166
Parcel: 12212301C

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.4

Permit Number - TD-DEV-0323-00166
Review Name: DEVELOPMENT PACKAGE NEW v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/11/2025 Commercial Plumbing REQUIRES RESUBMIT ACTIVITY NO. TD-DEV-0323-00166
ADDRESS/PARCEL: 1635 N BELVEDERE AV TUCSON, AZ 85712
The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.
COMMENTS:
Backwater Valve Required
1. The upstream manhole, #8549-01, has a rim elevation of 2475.83. The proposed fourplex has a FFE of 2475.52. If FFE is not at least 12 inches higher than the nearest upstream manhole, a backwater valve for the sewer line is required. Provide a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.