Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0226-00049
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2026 | Site Zoning Standard | APPROVED | |||
| 03/03/2026 | Historic | NOT REQUIRED | This is not in a National Register Historic District. Demolition of shade canopy is less than 50 years old. No historic review required. | ||
| 03/19/2026 | NPPO Standard | NOT REQUIRED | |||
| 03/19/2026 | Site Landscape Standard | NOT REQUIRED | |||
| 03/03/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0226-00049 (1st Review) Project: AUTO WASH EXPRESS - DEVELOPMENT PACKAGE FOR NEW SHADE CANOPY Location: 1435 W SAINT MARYS RD Review Date: 3/3/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Provide the development package case number, TD-DEV-0226-00049, adjacent to the title block on all sheets. 2. Provide a side profile construction detail to have a better idea of what the shade structure will look like compared to the original. a. Ensure to show the canopy supports similar to how the original is shown on sheet 2. 3. Provide dimensions relating a. The PAAL/Access Lane widths b. Setbacks/distances from property boundaries and existing structures If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 02/24/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 03/02/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | External Reviewers not required. No further action is required from the customer at this time. | ||
| 03/23/2026 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 03/24/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 02/25/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 02/27/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 03/17/2026 | ROW Engineering Review Standard | REVIEW COMPLETED | |||
| 03/02/2026 | ROW Review | REVIEW COMPLETED |