Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0226-00046
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/25/2026 | CDRC Review Coordinator Express | PENDING ASSIGNMENT | |||
| 02/25/2026 | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | Fire New Construction Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | NPPO Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | ROW Engineering Review Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | ROW Review | PENDING ASSIGNMENT | |||
| 02/25/2026 | Site Engineering Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | Site Landscape Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 02/23/2026 | OK to Submit - Engineering Fast | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0226-00046 (OK to Submit Review) Project: New SFR located in High School Wash FP Location: 939 E CADDIE ST Review Date: 2/23/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. Application incomplete – Grading plan does not provide all necessary information or details. a. Provide total cut/fill quantities as well as total area of disturbance on the plan set b. Show the full extent of the building fill pad along with associated slopes (3:1). This should be done in compliance with Sec 26-8.d.2. The pad should be sufficiently sized for beyond the footprint of the home c. Provide/show both existing and proposed spot elevations/contours as well as limits of grading. d. Dimensions associated with where the building is in relation to the site overall i. Setbacks from property lines ii. Distance from existing structures e. The plan set show a wall/fence – Provide details regarding this fence, as well as any details required such as flood venting necessary in the event it is a CMU wall proposed – ensure that this fence/wall was included when modeling for encroachment analysis i. If CMU wall, the analysis should review both with the wall there and if it wasn’t there – most conservative results will be used for review analysis. If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 02/25/2026 | OK to Submit - Zoning Fast | REQUIRES RESUBMIT | 1. Address Site Engineering comments. | ||
| 02/23/2026 | CDRC Application Completeness Express | REVIEW COMPLETED |