Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/30/2024 | Site Engineering | APPROVED | |||
10/03/2024 | CDRC Post Review | PENDING ASSIGNMENT | |||
10/03/2024 | Commercial Plumbing | REQUIRES RESUBMIT | The rim elevation and numbering of many of the manholes has been revised for this submittal. The following comments are based on the elevations of the current submittal: 1. Revise the site drawing to indicate that backwater valves will be required for lots 40, 168, 169, 170, 171, 172, 177, 178, 179, 180, 181, ,and 182 because the rim elevation of the next upstream sanitary manhole is above or less than 12” below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. 2. Revise the site drawing to indicate that backwater valves will not be required for lots 138 and 196 because the rim elevation of the next upstream sanitary manhole is 12” or more below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. |
||
09/16/2024 | CDRC Application Completeness | REVIEW COMPLETED | |||
10/03/2024 | ROW Engineering Review | REVIEW COMPLETED | DTM will continue reviewing ROW improvements through the PIA process. |