Review Date Reviewer's Name Type of Review Description Status Comments
09/30/2024 Site Engineering APPROVED
10/03/2024 CDRC Post Review PENDING ASSIGNMENT
10/03/2024 Commercial Plumbing REQUIRES RESUBMIT The rim elevation and numbering of many of the manholes has been revised for this submittal. The following comments are based on the elevations of the current submittal:
1. Revise the site drawing to indicate that backwater valves will be required for lots 40, 168, 169, 170, 171, 172, 177, 178, 179, 180, 181, ,and 182 because the rim elevation of the next upstream sanitary manhole is above or less than 12” below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
2. Revise the site drawing to indicate that backwater valves will not be required for lots 138 and 196 because the rim elevation of the next upstream sanitary manhole is 12” or more below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.
09/16/2024 CDRC Application Completeness REVIEW COMPLETED
10/03/2024 ROW Engineering Review REVIEW COMPLETED DTM will continue reviewing ROW improvements through the PIA process.