Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0224-00044
Parcel: 10602212A

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0224-00044
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/12/2024 Commercial Plumbing APPROVED
08/09/2024 NPPO APPROVED
08/12/2024 CDRC Post Review Express PENDING ASSIGNMENT
07/22/2024 ROW Engineering Review REQUIRES RESUBMIT TD-DEV-0224-00044
1. Correct keynote 1 to reference correct PAG driveway apron standard.

2. Identify concrete surface shown in the rights-of-way on site plan. If this is proposed sidewalk, call out PAG SD 200 and width of sidewalk. Sidewalk should be placed in alignment with the existing sidewalk east of site, a minimum of 3 feet from back of curb. Also, indicate that sidewalk terminations match the existing adjacent grade.

If you have any questions, please contact Richard Leigh. at 520-403-0970 or at arnold.leigh@tucsonaz.gov
08/09/2024 Site Landscape REQUIRES RESUBMIT Site Landscape Comments:
1. Ensure that Zoning comments are addressed prior to landscape section approval.
2. Attach the aerial photograph that was provided with this submittal to the NPPO Exception that was submitted prior. This will make it clear that the two documents are associated with each other.

Chad Keller, RLA
chad.keller@tucsonaz.gov
08/02/2024 Site Zoning REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Wyatt Berger
Lead Planner

PROJECT: Multifamily Development
Development Package (3rd Review)
TD-DEV-0224-00044

TRANSMITTAL DATE: August 2, 2024

DUE DATE: August 7, 2024

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC), Administrative Manual (AM) Section 2-06, and the Technical Standards Manual (TSM).

Per UDC Section 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year expiration date is August 2, 2025.

1. COMMENT: 2-06.4.9.O – Per UDC Table 6.3-2.A, when a residential use is adjacent to a residential zone, the required perimeter yards are ten feet or 3/4 the height of the exterior building wall, whichever is greater. Based on approved model plan TC-MDP-1223-01894, Zoning offers the following comments:

Based on a wall height of 18'-4", the required side perimeter yard is 13'-9"; the proposed perimeter yard is 12'-0" as measured from the building to the west lot line.

Based on a wall height under 13'-4", the required side perimeter yard is 10'-0"; the proposed perimeter yard is 8'-0" as measured from the staircase to the east lot line.

Based on a wall height of 17'-0". the required side perimeter yard is 12'-9"; the proposed perimeter yard is 11'-0" as measured from the second story porch to the east lot line.

Zoning acknowledges that an application for a Design Development Option (DDO) has been submitted. If the submitted DDO is approved, provide with your resubmittal a copy of your DDO decision letter. Zoning cannot approve TD-DEV-0224-00044 until the submitted DDO is approved.

If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov or at (520) 837-4951.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
08/02/2024 Zoning Modifications - DDO REQUIRES RESUBMIT FROM: Georgia Pennington, PLANNER
DATE: 6/13/24

COMMENTS:

1. This comment was not addressed: The setbacks requested on the DDO application must match the site plan. Please review the Site Zoning comments to revise your request, there should be three requests total.

If you have questions about this transmittal, contact me at georgia.pennington@tucsonaz.gov
07/08/2024 CDRC Application Completeness Express REVIEW COMPLETED