03/20/2023 NPPO APPROVED
04/11/2023 CDRC Post Review PENDING ASSIGNMENT
03/23/2023 Commercial Plumbing REQUIRES RESUBMIT 1. The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length from the upstream entrance of the cleanout. The section of building sewer downstream of CO-1 has a developed length of 107 feet. Reference: Section 708.1.1, IPC 2018.
2. Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson.
03/21/2023 Fire New Construction REQUIRES RESUBMIT -Cannot locate the UG fire service line

john.vincent@tucsonaz.gov
5203495581
03/22/2023 Site Engineering REQUIRES RESUBMIT TD-DIV-0223-00143 Autozone #5928
13__ W Ajo Way

Comments:
Format
1. Please ensure page numbers are correct and each page is numbered.
Documentation
2. This site was part of Development Package S09-081 with the two eastern parcels and has a master drainage plan. Provide the master drainage plan for review along with this development package and explain in the drainage report how the proposed development meets the goals of the master drainage plan.
3. Provide a narrative explaining how the proposed and current developments comply with the conditions of rezoning C9-09-10.
4. A cross access agreement will be required for access from eastern parcel.
5. Provide documentation when the existing water easement is vacated. This DP cannot be approved until the documentation is provided.
Design:
6. Show a sidewalk connecting the door on the south of the building to rest of the site and a pedestrian path to the trash enclosure.
7. Show the width of the sidewalk is at least 4’ adjacent to proposed bollards.
8. Please provide a dimension for the depth of the back-up spur on the west side of the parking lot.
9. Please provide the dimensions of the existing sidewalk along Ajo Way.
Content:
10. Please clarify the ambiguous sentence at the bottom of page 6 of the drainage report.
11. Address missing infiltration time information in the drainage report.

Faffs Riederer
Faffs.Riederer@tucsonaz.gov
04/11/2023 Site Landscape REQUIRES RESUBMIT PROJECT: AUTOZONE STORE #5928
ACTIVITY NO. TD-DEV-0223-00143
ADDRESS/PARCEL: -41-3730
ZONING: C-2

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
COMMENTS:
1. Ensure all Zoning and Engineering comments are addressed prior to the Landscape/NPPO comments.
2. Provide the development package case number, TD-DEV-0123-00111 adjacent to the title block on all sheets.
3. Provide a narrative outlining how the proposed and current development comply with the landscape conditions of the rezoning Case C9-09-10.
4. The tree legend is difficult to read, please scale back the size of the tree symbols to fit the legend.
5. A separate irrigation water meter is requires. Please label the new irrigation meter as “irrigation only”. UDC Technical Syandards 4-01.-.2. A.1.
6. Any and all planting and irrigation in the Right-Of-Way (ROW) needs approval from DTM prior to construction. Please reach out to David Marehefka (David.marhefka@tucsonaz.gov) for this.
7. Label sight visibility triangles and ROWs (existing and future) to all landscape plans.
8. Show all curb cuts/downspouts/splashpads on the landscape and the commercial rainwater harvesting plan.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
03/16/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Autozone #5928
Development Package (1st Review)
TD-DIV-0223-00143

TRANSMITTAL DATE: March 16, 2023

DUE DATE: March 26, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 22, 2024.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.2.D – The total number of pages listed on each sheet is not correct.

2. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DIV-0223-00143, adjacent to the title block on all sheets.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

3. COMMENT: 2-06.4.7.A.3 – List rezoning case number C9-09-10 adjacent to the title block on all sheets and provide the rezoning conditions on the plan. The proposed development does not match what is shown on the Preliminary Development Plan (PDP) dated 10/22/2009. Provide written documentation for the PDSD Rezoning Section, John Beall, John.Beall@tucsonaz.gov, that the proposed changes will not require a revised PDP.

4. COMMENT: 2-06.4.7.A.4 – General Note 3 the existing use is not correct and should be “Vacant”. The proposed use should be listed as General Merchandise Sales, excluding Large Retail Establishment subject to Use Specific Standards 4.9.9.B.1.

2-06.4.7.A.8 - For development package documents provide:

5. COMMENT: 2-06.4.7.A.8.b – Remove all references to lot coverage from the plan as it is not applicable.

2-06.4.8 - Existing Site Conditions
The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

6. COMMENT: 2-06.4.8.C - Dimension the width of paving, curbs, curb cuts, and sidewalks for both Ajo Way and Phoebe Ave.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

7. COMMENT: 2-06.4.9.H.5.a – The wheel stop located dimension show on the “HANDICAPPED PARKING SPACE” detail sheet 5. Review UDC Article 7.4.6.H.3 and provide the correct dimension.

8. COMMENT: 2-06.4.9.H.5.a – The mounting height shown for the handicapped sign is not correct and should be 84” to the bottom of the van accessible sign when mounted on a pole.

9. COMMENT: 2-06.4.9.H.5.d – Demonstrate how the requirements of UDC Article 7.4.9.B.1.e are met for the bicycle parking.

10. COMMENT: 2-06.4.9.L – The existing water easement shown to be vacated on sheet 3 will need to be vacated prior to approval of this DP.

11. COMMENT: 2-06.4.9.O – Show the required 90’ setback from the south property line, see rezoning condition 14.

12. COMMENT: 2-06.4.9.Q – Provide the square footage, height and specific use proposed within the footprint of the building.

13. COMMENT: 2-06.4.9.R – Demonstrate on the plan that a 4’-0” wide sidewalk is maintained between the proposed bollards and the building. Also provide the space of the bollards.

14. COMMENT: 2-06.4.9.U - Indicate graphically, where possible, compliance with conditions of rezoning.

15. COMMENT: 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also, provide a general note stating all signs require separate permits.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
02/17/2023 CDRC Application Completeness REVIEW COMPLETED
03/14/2023 CDRC Review Coordinator REVIEW COMPLETED external review requests added and sent
04/07/2023 External Reviewers - Arizona Department of Transportation (ADOT) REVIEW COMPLETED ADOT has no comments.
Thank you for the opportunity to review.
03/16/2023 External Reviewers - COT Parks & Recreation REVIEW COMPLETED Hello CDRC team,

On behalf of the City of Tucson Parks and Recreation Department, I have no comments on the above development application.

Tom Fisher
Project Manager
City of Tucson Parks and Recreation Department
900 S. Randolph Way
Tucson, Arizona 85716
(520) 837-8037
04/07/2023 External Reviewers - Pima Association of Governments REVIEW COMPLETED SENT FYI EMAIL PER SOP.
03/27/2023 External Reviewers - Pima County Addressing REVIEW COMPLETED Good morning,

TD-DEV-0223-00143 does not require review by Pima County Addressing. The site will require a new address. The applicant may submit an application for a new address to addressing@pima.gov.

Nicholas Jordan
Site Review Project Manager - Addressing Official
Pima County Development Services Department
201 N Stone AV – 1st Floor
Tucson, AZ 85701
(520) 724-9623
03/14/2023 External Reviewers - Southwest Gas REVIEW COMPLETED Sent FYI email per SOP
03/27/2023 External Reviewers - Tucson Airport Authority REVIEW COMPLETED Good afternoon,

Attached are TAA’s comments on TD-DEV-0223-00143. I have included copies of the TAA Avigation Easement document and Airport Disclosure Statement Form since these are referenced within the comment letter. Please let me know if you have any questions or need any additional information.

Thank you,

Scott Robidoux, C.M.

Manager of Planning







TUCSON AIRPORT AUTHORITY
7250 South Tucson Blvd, Suite 300
Tucson, Arizona 85756
Phone 520-573-8100
Direct 520-573-4811
03/14/2023 External Reviewers - Tucson Electric Power (TEP) REVIEW COMPLETED Sent FYI email per SOP
03/14/2023 External Reviewers - United States Postal Service (USPS) REVIEW COMPLETED Sent FYI email per SOP
02/22/2023 OK to Submit - Engineering REVIEW COMPLETED
02/22/2023 OK to Submit - Landscape REVIEW COMPLETED
02/23/2023 OK to Submit - Zoning REVIEW COMPLETED
03/23/2023 ROW Engineering Review REVIEW COMPLETED No Comments

David Stiffey

David.Stiffey@tucsonaz.gov
04/07/2023 Traffic Engineering Review REVIEW COMPLETED