Permit Number: TD-DEV-0223-00141
Parcel: 10707003D

Address:
1109 W GLENN ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW REVISION v.2

Permit Number - TD-DEV-0223-00141
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2024 CDRC Post Review PENDING ASSIGNMENT
10/31/2024 TSMR/PDMR - Engineering REQUIRES RESUBMIT 1. Comments from Andy Vera at Environmental Services:

The proposed TSMR may work if there is a minimum 18 ft (no less) clear area between the side wall bollards and 10 ft from the rear bollards to the front gate.
1. Must include all dimensions within the trash enclosure detail. Identify the spacing measurement between all bollards, between the face of the bollard to the rear and side walls, and between the two side wall bollards, 1 and 6. Refer to TSM 8-01.5.2 and 8-01.9.0 Figure 3A & 3B. Must also, identify anchors for securing gates in the open and closed positions.
2. Annotate within the detail the grade/slope will be a minimum 2% away from enclosure. Per TSM 8-01.5.2.G.