Permit Number: TD-DEV-0223-00141
Parcel: 10707003D

Address:
1109 W GLENN ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - TD-DEV-0223-00141
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/22/2023 CDRC Post Review PENDING ASSIGNMENT
02/22/2023 CDRC Review Coordinator PENDING ASSIGNMENT
02/22/2023 Commercial Plumbing PENDING ASSIGNMENT
02/22/2023 Fire New Construction PENDING ASSIGNMENT
02/22/2023 NPPO PENDING ASSIGNMENT
02/22/2023 ROW Engineering Review PENDING ASSIGNMENT
02/22/2023 Site Engineering PENDING ASSIGNMENT
02/22/2023 Site Landscape PENDING ASSIGNMENT
02/22/2023 Site Zoning PENDING ASSIGNMENT
02/22/2023 OK to Submit - Landscape REQUIRES RESUBMIT 1.There must be a NPPO or NPPO waiver.  An NPPO is required per UDC 7.7.3-B.   A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted or approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the UDC and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. 
2. Missing the irrigation plan. Missing Landscape Construction Details. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.
3. There will need to be a Commercial Rainwater Harvesting plan is required per UDC Technical Standards Manual – Section 4-01.3.0. and Section 5-01.0.0 Landscaping and Screening. Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov or 520-837-4988
02/15/2023 CDRC Application Completeness REVIEW COMPLETED
02/17/2023 OK to Submit - Engineering REVIEW COMPLETED 1. Include the required SWPPP in the next submittal.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
02/21/2023 OK to Submit - Zoning REVIEW COMPLETED