Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - TD-DEV-0223-00141
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2025 | Site Landscape Standard | APPROVED | |||
| 07/31/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Pima County Wastewater Reclamation requires the installation of a 4” riser and cleanout to grade,12” from the property line (i.e. prior to entering the right of way). See new HCS on DP-4.1. Reference: Pima County Standard Detail RWRD 401. | ||
| 08/05/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. See that zoning comments are addressed. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 07/29/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TWC Tucson Development Package (Revision - 1st Review) TD-DEV-0223-00141 TRANSMITTAL DATE: July 29, 2025 DUE DATE: July 30, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Per UDC Article 3.3.3.G.5.c, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is July 07, 2026. 2-06.4.7.A.8 - For development package documents provide: 1. COMMENT: 2-06.4.7.A.8.b – Remove the reference to “FLOOR AREA RATIO CALCULATION (FAR)” from the plan as FAR is not applicable to this site, see UDC Table 6.3-5.A. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2. COMMENT: 2-06.4.9.H.5 – As Glenn is designated as a Collector clearly demonstrate how a vehicle attempting to use the eastern most access off of Glenn can turn around onsite with out backing out into the Glenn right-of-way if the gate is closed and locked. All vehicle maneuvering shall be onsite. 3. COMMENT: 2-06.4.9.H.5.a – The accessible parking calculation is not correct. Per the 2018 IBC Table 1106.1 when 119 spaces are provided the required number of accessible spaces is 4 4. COMMENT: 2-06.4.9.H.5.a – Clarify why there are two different vehicle parking space calculations on the plan that do not match. 5. COMMENT: 2-06.4.9.H.5.d – Demonstrate how the requirements of UDC Article 7.4.9.B.1.e are met for the short-term bicycle parking near the new office building. 6. COMMENT: 2-06.4.9.O – Provide a street perimeter yard setback from the proposed office building to the future right-of-way line, UDC Article 6.4.5.C.2.a 7. COMMENT: 2-06.4.9.X – Provide landscape plans that clearly show compliance with UDC Articles 7.4.9.B & C are met for the proposed expansion. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 07/03/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 07/09/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | External Reviewers not required. No further action is required from the customer at this time | ||
| 07/28/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 07/07/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 07/08/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 07/10/2025 | ROW Engineering Review Standard | REVIEW COMPLETED |