| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/13/2024 | External Reviewers - Tucson Electric Power (TEP) | APPROVED | March 13, 2024 WO#T105407 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: WAREHOUSE WITH PARKING, PEDESTRIAN AND LANDSCAPING AREAS TD-DEV-0223-00139 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 2/15/2024. There are existing facilities within the development which are not depicted upon the plan; however, there do not appear to be any apparent conflicts to the new building. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918-8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our land Resources Department, TEPDEVREV@tep.com. Should you have any technical questions, please contact the area designer, Martin Salazar (520) 305-6713 msalazar@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power | ||
| 02/28/2024 | NPPO | APPROVED | |||
| 03/05/2024 | Site Engineering | APPROVED | |||
| 02/28/2024 | Site Landscape | APPROVED | |||
| 03/11/2024 | Site Zoning | APPROVED | |||
| 03/13/2024 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 03/13/2024 | Commercial Plumbing | REQUIRES RESUBMIT | The new building will still require the installation of a backwater valve because the FFE of the new building is still lower than the rim elevation of the next upstream manhole. The existing 2-story building could be at risk for a sewage overflow if its FFE is similarly situated below the rim elevation of the next upstream manhole. Plumbing fixtures located more than 12” above the rim elevation of the next upstream manhole (i.e. on the second floor) cannot discharge through a backwater valve. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. | ||
| 02/15/2024 | External Reviewers - Pima County Wastewater (RWRD) | REQUIRES RESUBMIT | The applicant is responsible for obtaining review and approval by Pima County, for projects involving RWRD sewers, on-site wastewater treatment facilities and public water systems https://www.pima.gov/1766/Wastewater-Reclamation. The applicant must provide an Approval letter from RWRD, prior to PDSD Approving the permit. | ||
| 03/11/2024 | ROW Engineering Review | REQUIRES RESUBMIT | TD-DEV-0223-00139 2111 E. 17th St. Comments: 1. On “Site Plan” sheet S2. Remove Note No. 10 from connecting to the street. End the 4’ sidewalk on private property, do not have in the Right of Way. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
||
| 02/06/2024 | CDRC Application Completeness Express | REVIEW COMPLETED | Per consulting with Nicholas Martell, we will start a new workflow within the existing workflow because application was in approved status and had not been issued. All reviewers will take a look at the new submitted documents. | ||
| 02/15/2024 | CDRC Review Coordinator Express | REVIEW COMPLETED | Review request email sent per ADOT, TEP. CDRC sent FYI email to PAG, USPS, SWG. | ||
| 02/23/2024 | External Reviewers - Arizona Department of Transportation (ADOT) | REVIEW COMPLETED | Good Afternoon, ADOT has no comments on this DEV. Thank you for the opportunity to review. |
||
| 02/15/2024 | External Reviewers - Pima Association of Governments | REVIEW COMPLETED | CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time. | ||
| 02/15/2024 | External Reviewers - Southwest Gas | REVIEW COMPLETED | CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time. | ||
| 02/15/2024 | External Reviewers - United States Postal Service (USPS) | REVIEW COMPLETED | CDRC sent FYI email to PAG, USPS, SWG. No further action is required from the customer at this time. | ||
| 02/29/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 02/12/2024 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 02/07/2024 | OK to Submit - Landscape Fast | REVIEW COMPLETED | |||
| 02/15/2024 | OK to Submit - Zoning Fast | REVIEW COMPLETED |