Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0126-00018
Parcel: 135074480

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0126-00018
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Commercial Plumbing Standard PENDING ASSIGNMENT
N/A Fire New Construction Standard PENDING ASSIGNMENT
N/A NPPO Standard PENDING ASSIGNMENT
N/A Site Landscape Standard PENDING ASSIGNMENT
N/A Site Zoning Standard PENDING ASSIGNMENT
01/28/2026 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-0126-00018 – Change of Use: Office/Call Center to Office/Manufacturing
Location: 1401 S PANTANO RD
Review Date: 1/28/2026

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Comments:
1. Provide the development package case number, TD-DEV-0126-00018, adjacent to the title block on all sheets.
2. Due to this development package being greater than one page, provide a sheet index. AM 2-06.3.12
3. Revise the plan set to provide Sight visibility triangles for all the site entrances, along Pantano RD in compliance with TSM 10-01.5.0. NOTE: Pantano RD is designated as an Arterial RD. This designation will be used for Table 5.3.
4. Include within the Waste stream calculations on the cover sheet, how the site will manage said waste. Include total containers and size of said containers. TSM 8-01.8.0

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
01/27/2026 CDRC Review Coordinator Express REVIEW COMPLETED NO EXTERNAL REVIEWERS
External Reviewers not required. No further action is required from the customer at this time.
01/22/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
01/26/2026 OK to Submit - Zoning Fast REVIEW COMPLETED
01/28/2026 ROW Engineering Review Standard REVIEW COMPLETED Add detectable warning strips to ADA ramps in public ROW.