Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0126-00014
Parcel: 13315299A

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0126-00014
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0126-00014 (2nd Review)
Project: Construction of a 1 story AutoZone retail auto-parts store
Location: 6910 E TANQUE VERDE RD
Review Date: 3/10/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases:

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Previous comment #5 not fully addressed. As a pathway connection leading to tanque verde RD is now proposed, there is still a lack of connection to Indian Ruins RD.
2. Previous comment #7 not fully addressed. The denoted striped pathway proposed along the southern portion of the new building is not sufficient in meeting the requirements found in TSM7-01.4.0. It will be required that this pathway be a sidewalk with vertical separation.
3. Previous comment #12 not fully addressed. Erosion protection should be shown extending below the finished grade of the basin floor. DSSDR 4.8.1.4 This should be clearly shown on the grading plan.
4. Previous comment #13 not addressed. There appears to be no keynotes/call-outs referring to a measurement device, and the descriptor boxes do not point to anything relating to this. For resubmission, include a keynote showing where these staking devices will be placed.
5. Minimum freeboard shall be 6 inches within basins constructed below natural grade DSSDR 4.4.1.1 Demonstrate this for the Proposed basin (Southeast corner)
6. Delineate the slope & slope treatment used for Basin #1P
7. Previous comment #3 not fully addressed. The trash enclosure detail #6 on sheet 8 is not compliant with minimum standards regarding a double container enclosure. This includes:
a. The minimum required clear space/area of 24’-8” X 10’-4”
b. The minimum total enclosure dimensions
c. The ramps slope being 2% away from enclosure as well as the enclosure slab sloping 1% to the gate
i. It’s recommended that developments use the Figures from TSM 8-01.9.0 directly or use them as a basis for minimum information requirements
ii. If deviations are desired from the standard double enclosures, then Environmental services approval will be required. The contact to reach out to at ES will be Andy Vera at Andy.vera@tucsonaz.gov. Please submit the approval provided for the resubmission of this development package.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
03/27/2026 Site Landscape Standard REQUIRES RESUBMIT PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: PLAN SET (DP) FOR AN AUTOZONE RETAIL AUTO-PARTS STORE
ACTIVITY NO: TD-DEV-0126-00014
ADDRESS: 6910 E TANQUE VERDE RD
ZONING: COMMERCIAL ZONE (C-1)
LAND USE: RETAIL COMMERCIAL
03.27.2026

THE PROPOSED PLANS HAVE BEEN REVIEWED FOR COMPLIANCE WITH APPLICABLE DEVELOPMENT STANDARDS FOR SITE LANDSCAPE, NATIVE PLANTS, AND RAINWATER HARVESTING, PER-THE-CITY OF TUCSON UNIFIED DEVELOPMENT CODE (UDC), TECHNICAL STANDARDS MANUAL (TSM), AND ADMINISTRATIVE MANUAL (AM).

RESUBMIT REVISED DRAWINGS ALONG WITH A DETAILED RESPONSE LETTER, STATING HOW ALL SITE LANDSCAPE AND NPPO SECTION REVIEW COMMENTS HAVE BEEN ADDRESSED.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Any revisions/updates to linework required by site engineering will need to be shown on the site landscape plans for consistency prior to approval.

2. The property boundary/ROW line is difficult to decipher along the north portion of the project. If there is a future ROW line associated with E Tanque Verde, please show and label the line. The street landscape border should be designed to the future ROW. If the existing ROW dimension shown is the true existing and future ROW line, then please label it as existing and future.

3. Include spot elevations that match the civil grading plans at curb cut inlets, outlets and at the bottom of the basins. This will provide quick references during site inspections.

4. The Blue Texas Ranger located at the rear of the SVT can grow up to 5 feet in height. They are likely okay, but to be safe, adjust their placement slightly or possibly choose a slightly smaller variety of plant.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
04/01/2026 Site Zoning Standard REQUIRES RESUBMIT 1. COMMENT: Provide an additional general note with the following verbiage: EXISTING USE IS "COMMERCIAL SERVICES - FOOD SERVICE". PROPOSED USE IS "RETAIL TRADE - GENERAL MERCHANDISE SALES", SUBJECT TO USE-SPECIFIC STANDARDS 4.9.9.B.3 AND 4.9.13.O.

2. COMMENT: Provide copy of lot combination acceptance or permit fee receipt as proof that lot combination with Pima County was submitted. Final Site Zoning of this development package cannot be granted without this information.

3. COMMENT: Provide a dimension on Detail 3, Sheet 8 between the wheel stop and the end of the parking space that conforms with UDC Figure 7.4.6-C, which requires 2.5’ between the front of the wheel stop and the end of the parking space.

4. COMMENT: No direct pedestrian circulation path from the building directly to the existing sidewalk along the N Indian Ruins Rd frontage is shown. Per UDC Technical Standards Manual 7-01.4.1.D, “Sidewalks must connect all areas of the development and must also connect to the pedestrian circulation path located along any adjacent street…”

5. COMMENT: Per UDC Technical Standards Manual 7-01.4.1.C., “A sidewalk is required adjacent to any parking space accessed by a PAAL where the space is located on the same side of the PAAL as any building and no other parking spaces or PAALs intervene (See Figure 2)” A cross-hatched area along the southern portion of the building is shown; a sidewalk with at least 6” vertical separation is required here instead.
03/26/2026 Commercial Plumbing Standard REVIEW COMPLETED
03/25/2026 External Reviewers - Tucson Electric Power (TEP) Standard REVIEW COMPLETED March 20, 2026
WO#T174427
City of Tucson
Planning and Development Services
Attn: CDRC Admin Team
Dear CDRC Admin Team
Subject: AUTOZONE AZ10907
TD-DEV-0126-00014
Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 1/21/2026. There are existing facilities within the development which are not depicted upon the plan. Existing facilities are not on the plans, but do not appear to be in conflict. See attached TEP map. Further: TEP Facilities & easements missing from development plans. TEP Easements Bk 4800 Pg 523, Bk 5890 Pg 1046, Bk 7322 Pg 717 & Bk 714.
Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.
To apply for electric service, please call the New Construction department at (520) 918-8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans.
If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department,
LandReviews@tep.com.
Should you have any technical questions, please contact the area designer,
Martin Rodriguez
(520) 991-5495
mrodriguez@tep.com
Sincerely,
Design Admins
Design Admins
Tucson Electric Power
03/31/2026 ROW Engineering Review Standard REVIEW COMPLETED As Noted -
Work performed in the Right of Way will require separate ROW - Development permit per scope of work performed