Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0125-00017
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2025 | Commercial Plumbing Standard | APPROVED | |||
| 02/27/2025 | NPPO Standard | NOT REQUIRED | There are no protected native plants in the area of the new cmu wall. Neither the NPPO or NPPO waiver are applicable for this wall project. | ||
| 02/27/2025 | Site Landscape Standard | NOT REQUIRED | |||
| 02/27/2025 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 02/26/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. Per the detail on sheet 3, the proposed screen wall will need a separate structural wall permit. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 02/25/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Dana Kepner Company – Site Wall Development Package (1st Review) TD-DEV-0125-00017 TRANSMITTAL DATE: February 24, 2025 DUE DATE: February 24, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is January 29, 2026. 2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS 1. COMMENT: 2-06.2.2 – As the project is for a site wall only and no expansion of building square footage is proposed, Zoning recommends that items such as new short- & long-term bicycle parking be eliminated from the plan or the comments below apply. 2-06.4.0 CONTENT REQUIREMENTS 2. COMMENT: 2-06.4.1 – Provide the email addresses, and phone number for the Owner listed on sheet 1. 3. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0125-00017, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 4. COMMENT: 2-06.4.7.A.4 – The existing and proposed use listed, “WHOLESALING”, is a Use Group not a Use. Review UDC Article 11.3.12 and clarify what type of wholesaling is proposed. 5. COMMENT: 2-06.4.7.A.6.a - As Glenn St. is designated as a Collector on the COT MS&R Map provide a general note on the cover sheet stating “THIS PROJECT IS DESIGNED TO MEET THE OVERLAY ZONE(S) CRITERIA, UDC ARTICLE 5.4 MAJOR STREETS AND ROUTES SETBACK ZONE (MS&R)”. 2-06.4.7.A.8 - For development package documents provide: 6. COMMENT: 2-06.4.7.A.8.b – Remove the reference to Floor Area Ratio (FAR) from the plan as it is not applicable. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 7. COMMENT: 2-06.4.9.H.5.a – The accessible parking space calculation is not correct. Per 2018 IBC Table 1103.1 when the total parking provided is 1 to 25 1 accessible parking space is required and should be a van accessible space. Zoning acknowledges that based on the proposed work there is no requirement to upgrade the accessible parking but it is highly recommended that you do so. 8. COMMENT: 2-06.4.9.H.5.a – The van accessible parking space calculation is not correct. Per 2018 IBC Section 1106.5 for every six or fraction of six accessible parking spaces, at least one shall be a van-accessible parking space. That said, the requirement for this site 9. COMMENT: 2-06.4.9.O – Per UDC Article 6.6.4.B.1 Perimeter walls are measured from the base of the wall that faces an adjacent property. Based on the wall detail shown on sheet 3 it appears that the wall height facing the street will be 6’-8”. This height exceeds the 6’-0” wall height allowed within the perimeter yard, UDC Article 6.6.2.I. Design Development Option for wall height within the perimeter yard will need to be submitted and approved. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Georgia Pennington at Georgia.Pennington@tucsonaz.gov”. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 01/23/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 01/31/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | External Reviewers not required. No further action is required from the customer at this time. | ||
| 02/07/2025 | Fire New Construction Standard | REVIEW COMPLETED | Per the 2024 IFC Section 506;The project requires a Knox box at the gate location. | ||
| 01/30/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 01/30/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED | |||
| 02/05/2025 | ROW Engineering Review Standard | REVIEW COMPLETED |