Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0125-00016
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/05/2025 | Commercial Plumbing Standard | APPROVED | |||
| 03/12/2025 | NPPO Standard | APPROVED | |||
| 04/10/2025 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 02/20/2025 | ROW Engineering Review Standard | REQUIRES RESUBMIT | TD-DEV-0125-00016 • 2401 S WILMOT RD 1. The pedestrian circulation path along the project property frontage must be brought into compliance with Section 10-01.4.0 of the UDC Technical Standards Manual. This includes the replacement of any non-compliant curb access ramps, as well as any sidewalk sections that are cracked, broken, or exhibit a cross slope greater than 2%. Identify and note on the site plan the specific sections of the pedestrian path along Wilmot Rd that require replacement. These sections should include areas where the sidewalk is cracked, broken, or where the cross slope exceeds 2%. If you have any questions, please contact Richard Leigh at Richard Leigh at richard.leigh@tucsonaz.gov |
||
| 03/14/2025 | Site Engineering Standard | REQUIRES RESUBMIT | 1. See that Landscaping comments are addressed, Engineering may have additional comments after they are addressed. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 03/12/2025 | Site Landscape Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: RECONSTRUCTED SCHOOL BUILDING AND PARKING LOT ACTIVITY NO: TD-DEV-0125-00016 ADDRESS: 2401 S WILMOT RD ZONING: C-2 COMMERCIAL ZONE LAND USE: CHARTER SCHOOL REVIEW #1 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape/NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. This is not a commercial land use, but the site does include a commercial scale parking area and required landscape and should include a commercial rainwater harvesting plan, or would “Charter School” land use be exempt from the CRWHO per the Charter School Exemption Letter T13SA00115? If the project is exempt, can a bold note be added to the landscape cover sheet that states why it is exempt from the Commercial Rainwater Harvesting Ordinance? 2. The landscape plan does call out all landscape areas to be depressed 6-9” which is great. The parking area islands do not show any contouring or callouts for the depressed landscape planting areas. At the minimum can callouts be added to those areas so that they aren’t missed during construction? They can be “rainfall only” catchment areas with no curb cuts. If the grading works towards the planting areas, then it would be preferable to have the curb cuts in strategic locations at inlets and outlets of the depressed planting islands in the parking area. Or coordinate with the civil engineer to make sure that a contour is added to the grading plan and match the linework on the planting plan. 3. Update the Native Plant Preservation general note on sheet 11 of 14 to see the NPPO Waiver. 4. Add PVC sleeves to all irrigation lines crossing hardscape. 5. Make sure trees and shrubs are on separate valves and show the individual lines for trees and shrubs on the irrigation plan. 6. Can the wording “screened rock” be added to the “SR” sized rock call outs? 7. Provide the development package case number, TD-DEV-0125-00016, adjacent to the title block on all sheets. 2-06.4.3 Thank you, Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 03/05/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Canyon Rose Academy Charter High School Development Package (1st Review) TD-DEV-0125-00016 TRANSMITTAL DATE: March 5, 2025 DUE DATE: March 5, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is February 9, 2026. Zoning acknowledges that this site qualifies for the charter school exemption, T13SA00115 exemption letter dated 04/30/2013 but the following comments need to be addressed. 2-06.4.0 CONTENT REQUIREMENTS 1. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0125-00016, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2. COMMENT: 2-06.4.7.A.1 – The existing zoning listed under Zoning and Land Use Note 2 is not correct and should be C-2. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 3. COMMENT: 2-06.4.9.H.5.a – As accessible vehicle parking is a building code issue the accessible parking space calculation shall include the number of van accessible parking spaces required and provided. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf. |
||
| 02/11/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added TEP PAG, USPS, SWG to the workflow. Review request email sent to TEP. FYI email sent to PAG, USPS, SWG. | ||
| 02/11/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 02/11/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 04/10/2025 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | April 7, 2025 WO#T141882 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Canyon Rose Academy Charter High School TD-DEV-0125-00016 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 2/11/2025. There are existing facilities within the development which are depicted upon the plan. There are possible conflicts with new water lines and existing TEP electric lines, please see redlined plans, attached. Further, attached is Docket 3723 page 119. Existing facilities must be removed or relocated prior to releasing easement. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Martin Rodriguez (520) 991-5495 mrodriguez@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 02/11/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 03/05/2025 | Fire New Construction Standard | REVIEW COMPLETED | Provide Knox access at all gates. Questions: patricia.shelton@tucsonaz.gov |
||
| 02/10/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 02/12/2025 | ROW Review | REVIEW COMPLETED | |||
| 02/13/2025 | Traffic Engineering Review Standard | REVIEW COMPLETED | Can the southern driveway be closed? Comments on plans. |