Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0123-00119
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/20/2023 | Site Zoning | APPROVED | COMMENT: Provide a copy of the required Design Review approval letter with your building plans , see PAD-15 Section C.6. | ||
10/23/2023 | CDRC Post Review | PENDING ASSIGNMENT | |||
10/23/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Provide the documentation for the shared drive / cross access agreement between this site and the site to the east. 2. The drainage report says the retention requirement calculations are included in Attachment 1, however, attachment 1 only has the hydrologic data sheets. Please provide the retention calculations including volume required and volume achieved for each watershed. 3. In order to map the proposed basins please provide in a separate document a site basin plan identifying all Retention/Detention basins on site. Each basin should be designated with basin details provided including Length, Width, Depth, slopes, and volume. A legible plan view and perpendicular section views at basin centerlines shall also be provided for all basins. 4. Per our conversation on Aug 9th and section 2.2.2 of the retention/detention manual - Sites may contain some impervious or disturbed areas which do not drain into first flush retention, however, I thought I was clear in the meeting that section 2.2.3 still applies – The total first-flush retention volume provided in each developed watershed shall satisfy the first-flush retention requirement for that watershed. The site is still proposing roughly half of the impervious surface in a watershed that doesn’t drain into a retention basin at all. The manual allows for some flexibility but that watershed needs some retention capture. Revise as needed. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
09/18/2023 | CDRC Application Completeness | REVIEW COMPLETED | |||
10/02/2023 | Entitlements | REVIEW COMPLETED | DRC Letter was submitted. No special exception required. -GS |