Permit Number: TD-DEV-0123-00114
Parcel: 118122550

Address:
1428 S 6TH AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE REVIEW v.1

Permit Number - TD-DEV-0123-00114
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/27/2023 Site Engineering APPROVED
03/02/2023 Site Landscape APPROVED
03/02/2023 CDRC Post Review Express PENDING ASSIGNMENT
02/28/2023 Commercial Plumbing REQUIRES RESUBMIT 1. Will the proposed modular office building be connected to water service and to the sanitary sewer or will it be utilizing the toilet facilities in the existing office building? Reference: Section 107.2.1, IBC 2018.
2. If the proposed modular office will be using the toilet facilities of the existing office building, provide calculations to show that the existing toilet facilities are adequate for the increased occupant load. Show that the path of travel does not exceed 500 feet. Reference: Sections 2902.1.1 and 2902.3.3, IBC 2018.
3. If the proposed modular office will not be using the toilet facilities of the existing office building, show the water service and the connection to the public sewer for the modular office. Reference: Section 107.2.1, IBC 2018.
02/27/2023 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: Flores Modular Office
Development Package (1st Review)
TD-DEV-0123-00114

TRANSMITTAL DATE: February 27, 2023

DUE DATE: March 02, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is January 30, 2024.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0123-00114, adjacent to the title block on all sheets.

2. COMMENT: 2-06.4.4.C – The section corners shown on the location map are not correct.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

3. COMMENT: 2-06.4.9.E – As this site is made up of two (2) parcels a lot combination is required. Provide a copy of the approved Pima County Assessor’s Combo Request form with the next submittal.

4. COMMENT: 2-06.4.9.H.5.a – The mounting height shown for the accessible sign is not correct and should be 84” to the bottom of the van accessible sign.

5. COMMENT: 2-06.4.9.H.5.d – The proposed short-term bicycle parking location does not meet the requirements of UDC Article 7.4.9.C.2.c.

6. COMMENT: 2-06.4.9.H.5.d – Demonstrate on the plan how the requirements of UDC Article 7.4.9.B.1.e are met.

7. COMMENT: 2-06.4.9.R – The striped area shown along the north and east side of the proposed modular and along the west side of the existing building, excluding the accessible access aisle, is required to be at a minimum a 4’-0” wide sidewalk physically separated from the vehicle use area, TSM Sections 7-01.4.2 & 4.3.

8. COMMENT: 2-06.4.9.R – Per TSM Section 7-01.4.1.A a sidewalk physically separated from the vehicle use area is required from the proposed modular to the street property line. This sidewalk is required to meet barrier-free accessibility for the physically disabled, TSM Section 7-01.3.2.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/24/2023 CDRC Application Completeness Express REVIEW COMPLETED
02/13/2023 CDRC Review Coordinator Express REVIEW COMPLETED
02/13/2023 Fire New Construction REVIEW COMPLETED
03/02/2023 NPPO REVIEW COMPLETED
01/25/2023 OK to Submit - Engineering Fast REVIEW COMPLETED
01/25/2023 OK to Submit - Landscape Fast REVIEW COMPLETED
01/31/2023 OK to Submit - Zoning Fast REVIEW COMPLETED
03/02/2023 ROW Engineering Review REVIEW COMPLETED TD-DEV-0123-00114
1428 S. 6th Ave.

Comments:
1. Curb returns on arterial streets must have a minimum radius of 25’.
2. Concrete curb per P.A.G. standard 209.
3. Concrete curb access ramps per P.A.G. standard 207 at each curb return.
4. Tie-in to existing sidewalk per P.A.G. standard 203.
5. NOTE: If entryway construction is intended at this location, it doesn’t appear that curb returns would fit at this location. A P.A.G. standard 206 concrete driveway apron would appropriately suffice.


David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov