Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0123-00097
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/28/2023 | Site Engineering | APPROVED | |||
| 12/13/2023 | Site Zoning | APPROVED | |||
| 01/23/2024 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 12/20/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Comment not addressed. A backwater valve may not be installed where the building sewer connects to the public sewer. [Third comment: Comment not resolved. Remove the mention of a backwater valve from Sanitary Sewer Service Notes #5 and add a note to the Utility Plan Notes requiring the installation of a backwater valve when future plumbing activities take place.] [Second comment: Access is required for a backwater valve so you cannot locate it at the sewer tap.][Initial comment: The rim elevation of the next upstream sanitary manhole (9784-09, 2329.32’) is higher than the first floor elevation (2328.10’). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.] | ||
| 01/23/2024 | External Reviewers - COT Environmental Services | REQUIRES RESUBMIT | I was emailed a copy of the solid waste enclosure detail from the architect drawings which is acceptable, however, the detail drawings must be included within this DP for approval. Andy Vera (520) 837-3798 Andy.Vera@tucsonaz.gov |
||
| 12/01/2023 | CDRC Application Completeness Express | REVIEW COMPLETED |