| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/21/2023 | NPPO | APPROVED | |||
| 08/21/2023 | Site Landscape | APPROVED | |||
| 11/02/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 09/05/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Comment not resolved. Remove the mention of a backwater valve from Sanitary Sewer Service Notes #5 and add a note to the Utility Plan Notes requiring the installation of a backwater valve when future plumbing activities take place. [Second comment: Access is required for a backwater valve so you cannot locate it at the sewer tap.][Initial comment: The rim elevation of the next upstream sanitary manhole (9784-09, 2329.32’) is higher than the first floor elevation (2328.10’). Provide a note on the plans requiring the installation of a backwater valve when future plumbing activities take place. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.] | ||
| 11/02/2023 | External Reviewers - COT Environmental Services | REQUIRES RESUBMIT | ES Comments are as follows: 1. No detailed drawings of enclosures included within the DP. This was also noted in the 1st submittal review comments…No enclosure detail provided. Include detail drawings of enclosure with dimensions. TSM 8-01.4.A & 8-01.5.2. Refer to TSM 8-01.9.0, figure 3B, single container enclosure. Provide detail drawing of enclosure fully dimensioned. All other conditions are met and acceptable. Thanks, Andy Vera City of Tucson -Environmental Services Accounts Representative Supervisor (520) 837-3798 |
||
| 08/21/2023 | Site Engineering | REQUIRES RESUBMIT | 1. Comment 1 was not addressed, provide either reference to TSM 8-01.9 Figure 3, or include a detail showing compliance with TSM 8-01. This must be included in the development package, and reference to a detail in the architectural plans is not sufficient. Scott Haseman scott.haseman@tucsonaz.gov |
||
| 08/16/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Paul Camarena PDSD Zoning Review Section PROJECT: 4137 N 1ST AV Development Package (3rd Review) TD-DEV-0123-00097 TRANSMITTAL DATE: August 16, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is January 9 , 2024 . SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) As there are changes to the site, these changes will required PDP modification 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). This comment is still applicable please provide the information for all sheets 1. COMMENT: 2-06.4.2.D – This comment is still applicable, please insure that the page numbers are correct. 2. COMMENT: 2-06.4.7.A.6 – Per rezoning “all dumpsters, loading zones shall be located a minimum of 50 feet from the boundary of the residentially zoned property immediately to the west of the rezoning site. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. This comment is still applicable, Per UDC section 7.4.6.H.1. “Barriers, such as post barricades or wheel stop curbing, are required in a vehicular use area to prevent vehicles from extending beyond the property lines , to prevent cars from damaging adjacent landscaping , walls, or buildings , overhanging adjacent sidewalk areas , and/or driving onto unimproved portions of the site .” 3. COMMENT: 2-06.4.9.H.5.a - This comment is still applicable please provide a parking detail that accurately depicts the proposed parking 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. 4. COMMENT: 2-06.4.9.H.5.d – Clarify the location of the long term bicycle parking, This comment is still applicable key note 24 appears to be a short term bicycle parking, provide a detail for both the long term and short term parking. 2-06.4.9.L - All proposed easements (utility, sewer, drainage, access, etc.) are to be dimensioned and labeled as to their purposes and whether they will be public or private. The easements may have to be recorded and the recordation information added to the development package prior to approval. This comment is still applicable “the recordation information added to the development package prior to approval 5. COMMENT: 2-06.4.9.L - Provide the information noted by the standard, 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. This comment is still applicable, show the required setback from the future property line since dedication is being proposed on this site. 6. COMMENT: 2-06.4.9.O - Provide thesetback as noted by the standard above. Show the required and the proposed setback. For nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan , whichever is greater. For nonresidential and multifamily development abutting a Local Street : the minimum required street perimeter yard is 20 feet, as measured from the street property line . ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
| 08/11/2023 | CDRC Application Completeness Express | REVIEW COMPLETED |