Permit Review Detail
Review Status: Requires Resubmit
Review Details: PRIVATE UTILITY v.1
Permit Number - TC-UTL-0923-00089
Review Name: PRIVATE UTILITY v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/24/2023 | Water - PDSD | APPROVED | |||
10/18/2023 | Commercial Electrical | NOT REQUIRED | |||
10/19/2023 | Site Engineering | NOT REQUIRED | |||
10/16/2023 | Site Zoning | NOT REQUIRED | |||
10/24/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
10/24/2023 | Commercial Plumbing | REQUIRES RESUBMIT | Revise the section of the building sewer located between cleanout C.O.-1 and the existing cleanout. The maximum distance between cleanouts shall be 100-feet, measured along the developed pipe length from the upstream entrance of the cleanout. Cleanout C.O.-1 has a vertical drop of approximately seven feet which limits the horizontal distance to the next cleanout to 93 feet. Reference: Section 708.1.1, IPC 2018. | ||
09/25/2023 | PDSD Application Completeness | REVIEW COMPLETED |