Permit Review Detail
Review Status: Requires Resubmit
Review Details: PRIVATE UTILITY v.1
Permit Number - TC-UTL-0626-00091
Review Name: PRIVATE UTILITY v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/09/2026 | Site Engineering - Standard | NOT REQUIRED | |||
| 07/23/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/23/2026 | Commercial Plumbing - Standard | REQUIRES RESUBMIT | Private water service lines may not cross property lines to serve another parcel. The southernmost proposed 5/8” water meter appears to be located on a different parcel and the water service line crosses over a property line to serve the new duplex. This is not permitted per Tucson Water’s Remote Water Meter Policy. Tucson Water’s Remote Meter Policy No. IV-B.08, Eff. 07/14/2009 requires all of the following: a. Each lot must have its own water meter. b. The water meter for any given lot must lie within that lot’s frontage onto a public street, private street, or utility easement that contains an existing water main that can serve that lot. c. The private water line from a water meter to building must lie on just one lot. The private water line from a water meter to a building may not encroach into, or cross a second lot, even in a private water easement. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov |
||