Permit Review Detail
Review Status: Requires Resubmit
Review Details: UTILITIES REVIEW v.1
Permit Number - TC-UTL-0526-00071
Review Name: UTILITIES REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2026 | Commercial Building - Standard | APPROVED | |||
| 06/23/2026 | Site Engineering - Standard | APPROVED | |||
| 06/12/2026 | Outdoor Lighting - Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 07/07/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/12/2026 | Commercial Electrical - Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-UTL-0526-00071 (1501 E METRIC PL TUCSON, AZ 85713) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide the conductors size and type for the Transformer Secondary conductors to the 600A MSP. Show all wiring methods in detail for all new conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. |
||
| 06/23/2026 | Site Zoning - Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner Planning & Development Services Department – Current Zoning Review Section PROJECT: TC-UTL-0526-00071 – Commercial – Cell Tower AZ02-150 Cledus 1501 E METRIC PL TUCSON, AZ 85713 (I-2 Zoning) Commercial Building Review – 1st Review TRANSMITTAL DATE: June 23, 2026 This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). 1. COMMENT: Add the TC-UTL-0526-00071 permit number to all the sheets. 2. COMMENT: Add the TP-ENT-0725-00015 permit number to the PDP stamp in the title blocks. 3. COMMENT: Add the TD-DEV-0323-00162 permit number to all the sheets. 4. COMMENT: Update the use on the T-1 sheet from unmanned communications to communications, wireless. 5. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 1. Corrected utilities permit 2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code |
||
| 07/07/2026 | Entitlements - Standard | REVIEW COMPLETED | |||
| 05/28/2026 | Fire New Construction - Standard | REVIEW COMPLETED | |||
| 05/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |