Permit Number: TC-RES-1225-06180
Parcel: 113094560

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1225-06180
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/14/2026 Residential Building - Standard REQUIRES RESUBMIT TC-RES-1225-06180
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance with component sizes. The 2024 IRC is in effect for first permit submittals after Jan 1, 2026.

Provide a response letter on separate file when submitting the updated construction plan set.

Field welding requires a completed special inspection request form for review with the permit plans, R109.2. Obtain an inspector and provide a certified inspector seal on the form found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Inspections

SITE PLAN:

1. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. Provide compliance with R302.1 (City of Tucson Amended) by removing the roof placed within 3 feet to the property line or provide a complete wall barrier (without openings) with not less than one-hour fire-resistive construction in compliance with IBC Table 721.1(2).

PLANS:

1. Clarify keynote #2.01 shown on the Foundation Plan, R106.1.1.

If you have any questions, please contact:
Kenneth.VanKarsen@tucsonaz.gov
City of Tucson Residential Plan Review
12/31/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1225-06180
Location: 1019 E ALTA VISTA ST
Review Date: 12/31/2025
A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal.

Residential Engineering Comments:
1. The site plan must include more information and updated measurements. The property dimensions from the Pima County Assessor do not match the site plan (55.0’ x 126.0’).
2. Please show 18’ Alley to the North.
3. Provide measure from property line to top of curb of Alta Vista.

Additional comments may be forthcoming.
If you have any questions or concerns, please contact Dylan Molina.
Dylan.Molina@tucsonaz.gov
01/12/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-1225-06079
1019 E Alta Vista St., Tucson, AZ 85719
Carport/Ramada (1st Review)

TRANSMITTAL DATE: 1/12/2026

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.


1. Per UDC 6.4.5.C.1., the front perimeter setback is 20’. Exceptions are made for carports. Carports may extend 10 feet into the required front perimeter yard. As shown on the site plan, the carport encroaches beyond the 10’ front perimeter setback and also encroaches into the east side perimeter setback. The side perimeter setback, per UDC Table 6.3-2 is 6’ or 2/3 the height of an exterior wall, whichever is greater. The measurements for both would be the distance between the property line and the nearest support post. For the carport to be constructed in its proposed location, a Design Development Option DDO application must be submitted and approval obtained through that process.

To submit an application for a DDO, please resubmit the package using the link and follow the instructions below:

www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf Submit a DDO application under the Zoning Modification sub-record that you will create . For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf

For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov

Note: Until the DDO has been approved, please do not resubmit the package because Site Zoning will not be able to approve the permit. Please include the DDO approval letter with the package.

2. Per UDC Table 6.3-2.A., the maximum lot coverage allowed for the R-2 zone is 70% for single-family development. Under Lot Coverage Calculations on the site plan, do not include any open structures to calculate total lot coverage. Per UDC 6.4.3.B3.a-c., lot coverage includes all enclosed structures and the vehicle use areas. Please recalculate the total lot coverage percentage.
3. For clarity, the Lot Coverage Calculations box labels the shop as an accessory structure. Please list this as a shop.

4. The two shade structures in the northeast side of the site appear to encroach into the 6’ perimeter setback. Staff found no permits for these shade structures. Please show the approximate distances from the support poles to the lot lines and either add these to your DDO application or provide proof of neighbor approval (the same neighbor who provided a waiver for the carport and the neighbor at 1020 E. Glenn St. north of the alley). Please place this waiver directly on the site plan.

5. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
12/31/2025 PDSD Application Completeness Express REVIEW COMPLETED