Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1225-06146
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/26/2026 | Residential Building - Standard | APPROVED | |||
| 12/31/2025 | Residential Engineering | NOT REQUIRED | |||
| 01/26/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/09/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston Planner PROJECT: TC-RES-1225-06146 3330 N Jackson Av, AZ 85719 Porch Addition (1st Review) TRANSMITTAL DATE: 01/09/2026 This site is located in the RX-2 zone (UDC 4.7.7). A single-family residence is a permitted use in this zone (Table 4.8-1). RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The site plan is missing information required for a Site Zoning Review. Please use the following link to find a site/plot plan example and the required items for your next submittal: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example Some examples of missing items include: a. The zoning for the subject lot and the lots surrounding the lot (RX-2). b. Owners’ names c. Legal description of lot (RICHLAND HEIGHTS N142' LOT 6 BLK 17) d. Lot dimensions e. Distances from each structure to the property lines and between each other. f. An engineer scale g. Elevations for the porch, demonstrating the height h. Dimensions, square footage, and labels for all structures on the site plan i. Lot coverage, meaning the square footage for all enclosed structures and vehicle use areas divided by the total square footage of the lot. j. The distance from the middle of Jackson to the west property line (30’ per paving plan I-817_007 found at https://maps-and-records.tucsonaz.gov/construction-plans/details/I-671 2. Aerial Pictometry from MapTucson and Pima County Maps show a shade structures along the southwest property line and a shed along the southeast property line. Staff find no permits for these structures and when solar permits were issued, the structures were not reviewed per stamped plans (TC-RES-0723-06840). Per UDC Table 6.3-1.A, the front, rear and side perimeter setbacks are 20’ measured from the property line. These structures appear to be located within the perimeter setbacks. Please ensure these structures are included in the next site plan and provide the square footage of the shed and dimensions of all structures as indicated in Comment 1, above. 3. Per UDC 6.4.5.D.3.a., a shade structure may project up to ten feet into the required perimeter yards. To mitigate a projection of the shade structure closer to the front perimeter yard, a Design Development Option approval is necessary. To submit an application for a DDO, please resubmit the package using the link and follow the instructions below: www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo-for-setback-and-height.pdf Submit a DDO application under the Zoning Modification sub-record that you will create . For instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov 4. With regard to the shed in the southeast corner within the 20’ perimeter setbacks, securing approval be the neighbors is an option to proceed with permitting. In the event a neighbor approval cannot be obtained, this shed can be added to the DDO application for the shade structures in the southwest corner of the lot. A block, signed by each neighbor affected by the setback (the property owners located at 3215 E Lind Rd and 2301 N Jackson Ave), could read something similar to the following: I/we are the owners at (address). I/we have seen the site plan and have no objection to the structures being located___ ft from our property line. Signed:_________ Date:____ 5. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov |
||
| 12/31/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |