Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1225-06081
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/21/2026 | Residential Building - Standard | APPROVED | |||
| 01/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/29/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1225-06081 Location: 2417 S KEVIN DR Review Date: 12/29/2025 A Comment Response letter is required. Please address all reviewer’s comments in a separate document with all required documents for resubmittal. Residential Engineering Comments: 1. This project/site resides within the recognized Rolling Hills Wash COT flood hazard zone and will require the submission and approval of a Floodplain Use (FPU) Permit with Elevation Certificate. The FPU permit is a separate permit that must be submitted within the "Sub-Records" tab of this associated building permit through TDC-Online. 2. Flood venting will be required according to Tucson Code PART II Chapter 26, Section 26-11.2.(8). For resubmission of the building permit for the shed and submission for the FPU permit, have the flood vents delineated on the construction plans along with a detail showing the dimensions of the vents. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19689 3. A minimum of two openings will be required. The vents will have a total net area of not less than one square inch for every square foot of enclosed area. Openings may be equipped with screens, louvers, valves, or other coverings or devices if they permit the automatic entry and exit of floodwater. 4. Residential Engineering will be unable to approve permit (TC-RES-1225-06081) until the associated FPU permit with elevation certificate process has been approved. If you have any questions or concerns, please contact Dylan Molina. Dylan.Molina@tucsonaz.gov |
||
| 01/02/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-1225-06081 2417 S KEVIN DR 24'x20' Non-livable detached accessory structure for use as a garage/storage (1st Review) TRANSMITTAL DATE: 1/2/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 -.9. Comment: Please include the following details in the site plan upon next submittal: 1. lot coverage, including line items for existing under roof area, vehicular use area, proposed shed SF, and total lot coverage; 2. the zoning designation of this site and those adjacent – all R-1; 3. the legal description of this site, which is STONEGATE LOT 87; 4. draw, label, dimension, and include setback measurements of all existing structures on the site, including existing storage sheds and accessory structures. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 12/26/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |