Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADU v.1
Permit Number - TC-RES-1225-06066
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2026 | Residential Zoning | APPROVED | |||
| 01/06/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/29/2025 | Addressing Validation | REQUIRES RESUBMIT | The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this ADU. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit. For questions: PDSD-Residential@tucsonaz.gov | ||
| 01/05/2026 | Residential Building | REQUIRES RESUBMIT | TC-RES-1225-06066 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings. Remove the 2015 IRC references from the plans, sheet E1 and P1.. The proposed dwelling does not qualify for an Accessory Dwelling Unit with a maximum 1000 SF size. Reduce the dwelling area or relabel the title blocks on each sheet of the plan set to SFR single family residence. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. GENERAL COMMENTS for SFR: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Sustainability-Codes 1. Plans submitted for a newly constructed one- or two-family dwelling require compliance with design ordinances for handicap, photo-voltaic, gray water, and EV charging preparations. Design Ordinances adopted by the City of Tucson. 2. Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson Ordinance #10463 on 10/16/2007. Notate accessible route, minimum door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. This requirement applies to both SFR and ADU. 3. Plans submitted for a newly constructed one- or two-family dwelling after July 1, 2009 require a solar photo-voltaic system, or future installation preparation City of Tucson Ordinance #10549 . a. Show a minimum 300 SF clear solar-ready zone on a roof or framing plan, T103.3. Model plans should show four typical south facing roof surfaces. b. Label a double breaker space for future Photo Voltaic on the panel schedule opposite end from the main/supply side, T103.9. Provide a future PV breaker space at the last panel space. 4. Plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, require gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Additional gray fixture drains are optional. Show a second clothes washer standpipe plumbed to an exterior wall above grade when feasible, or a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations 5. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space. SITE PLAN: . 1. Each dwelling building requires a street address assigned with a Pima County application, R319. Show Pima County assigned unit numbers at each dwelling on the site plan. 2. Clarify the location of electric service conductors to the existing dwelling, R106.1.1. Providing a minimum 8-foot clearance above the proposed dwelling roof for an overhead line may not be a feasible design, E3604.2.1. Relocated service requires coordination with TEP. PLANS: 1. Show a maximum ½” floor elevation changes at a notated accessible route entrance on the floor plan, R106.1.1. 2. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. PLUMBING PLANS: 1. Show the water heater rating, P2801.1. MECHANICAL PLANS: 1. Provide (an HVAC system with fresh air intake) whole-house mechanical ventilation with controlled exhaust, R303.4; N1103.6 & M1505.4. Identify the device model number providing an adjustable setting and note the minimum continuous setting. A two or three-bedroom dwelling under 1501 SF requires a 45 CFM continuous setting. ELECTRICAL PLANS: 1. TEP may require a dual service panel for the property at the closest building to the service transformer. A service line change or a new meter location should be coordinated with TEP for approval. 2. Provide the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2. 3. The dishwasher/disposal may use a single 20A circuit, E3703.7 amendment. Show the circuit on the panel schedule. 4. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to plans. 5. Provide a location description for circuits 15 and 17. OUTDOOR LIGHTING CODE 1. Identify full cutoff fixtures on the plans, OLC 401.3.3. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Energy Certificate: (Mandatory) place near the indoor furnace or in utility room, N1101.14. Add notation to plans. Please contact the plans reviewer if you have any questions: Ken Van Karsen PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
||
| 01/06/2026 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1225-06066 Location: 115 W LEE ST Review Date: 1/06/2026 Site Engineering Comments: 1. MapTucson shows a fence between the existing building and proposed SFR. If the fence still exists, show on plans. 2. Please dimension width of alley on site plan. If you have any questions or concerns, please contact Corey Hines Corey.Hines@TucsonAZ.gov |
||
| 12/29/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |