Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1225-06044
Parcel: 111080950

Address:
2631 N DODGE BL

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1225-06044
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/13/2026 Residential Building - Standard REQUIRES RESUBMIT Please review the comments below and resubmit with a response letter once the comments are addressed.
1. Show the location and size of buildings, utility meters and gas, water, electric and sewer or septic lines from property line to building, R106.1.1.
2. Provide a wood framing plan, R317.1
3. Show a floor plan labeling all proposed functions of rooms and spaces, R106.1.1. Bedrooms require compliant egress to the exterior. Include dimensions and show all doors, windows, fixtures and appliances in the construction area.
4. Provide complete drawings of all elevations, R301.1.
5. Indicate all materials used; stucco, concrete block, glass block, roofing system, siding, veneer, etc., R301.1.
6. Show plumbing penetrations in the fire-resistance-rated wall in compliance with R302.4.2.
7. Show smoke and carbon monoxide detector installation outside of bedroom doors, R315.3. This is required as permitted work is done within existing dwellings.
8. Clarify the location of supply ducts (exposed, within chase or exterior), N1103.2.3.
9. Provide an equipment specification list including the (fans, furnace, and AC) size or capacity, M1302.1.
10. Show the location of each outlet on the Electrical Plan, E3404.12.
11.Provide a Riser Diagram with a single service panel. E3607.
12/31/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Roxanne Johnston
Planner

PROJECT: TC-RES-1225-06044
2631 N Dodge Bl., Tucson, AZ 85716
SFR Remodel & Addition (1st Review)

TRANSMITTAL DATE: 12/31/2025

This site is located within the R-2 Zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed.

1. A site plan for Zoning Review has not been provided. Provide a site plan. Please visit https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example and add the required information. Below are a few examples of what the site plan needs to contain.
a. Owner name and address
b. Site address
c. Lot size: approx.. 7,748 sq, ft, per Pima County: https://gis.pima.gov/maps/detail.cfm?&parcel=111080950
d. The lot and abutting properties’ zoning: R-2
e. The lot’s legal description: Grantland Acres N60’ of Lot 10 Blk 4
f. Lot dimensions: 60’ X 119’-94” https://www.asr.pima.gov/ParcelData/Map/Arm/MP06/06091_02.PDF
g. North arrow
h. Engineer’s scale: e.g. 1” = 10’
i. Locations, uses, dimensions and square footage of all structures on the lot.
j. Street name
k. Utilities

2. Provide construction plans with building elevations.

3. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review.

Please note that setbacks for the R-2 zone per Tucson’s Unified Development Code (UDC) Table 6.3-2.B., the front perimeter setback is 20’ and the sides and rear of interior lots are 6’ or 2/3 the height of an exterior wall as explained in UDC 6.4.5. Encroachment in these setbacks will trigger other land use applications.

If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov .
12/23/2025 PDSD Application Completeness Express REVIEW COMPLETED