Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.2
Permit Number - TC-RES-1225-06043
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/31/2025 | Residential Building - Standard | APPROVED | Requires resubmit. Please note the following: 1. Provide overall dimensions of structure (height, width length). 3. Provide distance to neighboring property line. The roof structure may not extend to a point closer than 3 feet from the neighboring property line without fire rated protection for fire spread. 4. Show the size and location of each support footing, R106.1.1. 5. Show a complete cross-section detail with post to foundation fasteners, R407.3 & R507.4.1. 6. Provide a Roof Framing Plan showing the beams sized for supporting live and dead structural loads (Table R602.7(3)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. 7. Provide a Roof Framing Plan showing the rafters sized for supporting live and dead structural loads (Table R802.4.1(1)) or provide an engineer’s calculation, design, and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1. Prefab structures have engineered plans available from the supplier which are included with the submitted site plan. |
||
| 01/07/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/07/2026 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Claire Leighou, Planner PROJECT: TC-RES-1225-06043 814 W CALLE ADELANTO Adding corrugated metal roof to existing carport (2nd Review) TRANSMITTAL DATE: 1/7/26 Please resubmit revised drawings with a detailed response letter stating how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10. Comment: Please include a revised plot plan with the next submittal. Refer to the sample plan (linked below) as a guide. An aerial image with annotations may be submitted in place of a traditional plot plan, as long as it has all of the required information. The plan should include the following: dimensions of the existing carport, height, and setback measurements to property lines; property address and owner information; north arrow and engineer scale (e.g. 1”=10’); legal description - ADELANTO LOT 3 & PTN E11.48' N55.47' LOT 4 BLK 7 per Pima County Geographic Information System (https://gis.pima.gov/maps/detail.cfm?&parcel=11515521A); property lines and dimensions – lot 522B, per County Assessors records map (https://www.asr.pima.gov/ParcelData/Map/Arm/MP05/05042_04.PDF); zoning designation – R-2 Residential; footprint of all existing structures and setback measurements; label the adjacent streets (W Calle Adelanto and W Calle Retama); Lot coverage calculations; The example plot plan can be found here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Claire Leighou at claire.leighou@tucsonaz.gov. Thank you! |
||
| 12/30/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |