Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1225-06022
Parcel: 136080350

Address:
9630 E 29TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.2

Permit Number - TC-RES-1225-06022
Review Name: RESIDENTIAL ADD/ALT v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/13/2026 Residential Building - Standard APPROVED
01/13/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/13/2026 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-1225-06022 – Residential Building – Enclosed patio to add new bedroom and office, added shed, carport & metal fence around carport per CE-VIO1025-04461
9630 E 29TH ST TUCSON, AZ 85748 (R-1 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: January 13, 2026

This site is in the R-1 Residence Zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9 for 1 unit; 4.9.7.B.1 - .9, & .11 for 2 units (min. 10,000 sq ft lot size required).

Plan review for the above referenced enclosed patio to add new bedroom and office, added shed, carport & metal fence around carport has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The site plan provided is incomplete.

Provide a site plan that meets the requirements show in the plot plan example at the following link: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example

Specifically:

A. Draw, label and dimension everything that exists on the property to a SCALABLE drawing graphic and provide dimensions of any structure as it relates to nearby structures and property lines and provide the heights (measured from above finish grade to top of wall, etc.) of those structures that run parallel-perpendicular to any nearby adjacent property lines. Provide heights at various locations along the fence/wall if applicable.

B. Draw, label and dimension all setbacks. Setbacks for side and rear property lines are 6’-0” or 2/3 the height of any structure flanking the south, west and east property lines, whichever is distance is greater. The front yard setback is 20’-0”.

C. Refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=136080350 to locate and provide the parcel number, legal description, subdivision name, book and page numbers, township-section and range, sequence number on the plot plan.

D. Draw, label and dimension all property lines, (provide accurate property line lengths) to be reflective of information on Pima County’s website. Refer to Pima County’s website https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=21057. The math of the property line lengths will produce the total parcel square footage.

E. The lot coverage calculation has not been addressed. Per UDC Article 6.4.3.C.1.a roofed areas, porches, open on at least one side are NOT included in the calculation and per UDC Article 6.4.3.B.3.b Vehicular use areas, measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved are included in the lot coverage.

Calculate (measure) square footage of every enclosed (NOT open structures like a porch, ramada, carport) structure on site and all vehicular use area (driveway, parking, turnaround, backup) and input into lot coverage calculation table. A carport would be calculated under vehicular use area. These separate ‘category numbers’ are added together and divided by the total parcel square footage to produce the lot coverage percentage that demonstrates compliance (or not).

F. Draw, label and dimension the principal residence graphic to be representative of that via Pima County’s website (property record card) https://www.asr.pima.gov/ParcelData/prc/13608/0350.pdf . Include any/all unpermitted additions, modifications and label.

G. Draw and label front curbs and sidewalks along E 29th St per the paving plan on record https://maps-and-records.tucsonaz.gov/construction-plans/details/I-71-037.

H. Provide dimension from centerline of E 29th St to curb.

I. Provide zoning labels on all four sides of this parcel. including this parcel (All R-1).

J. Provide missing site plan scale and corresponding graphic scale.

2. COMMENT: Per UDC 6.6.3.C. standard, detached accessory buildings, including accessory dwelling units, are not permitted in the buildable area extending the full width of the lot between the principal building and front street lot line, except for shade structures or carports not over 400 square feet in floor area, terraces and steps not over three high above the natural grade, paved areas, and fences or walls. Carport is currently dimensioned as 24’-0” x 20’-0”, totaling 480 square feet. Adjust design to meet standard.

3. COMMENT: Per TABLE 6.4.5.C.1.a., “For single-family and duplex development, the minimum required street perimeter yard is 20’-0” measured from the street property line”

Additionally, per 6.4.5.D.3.a. “Shade structures or carports may project up to 10’-0” into required perimeter yards. Such architectural features include, but are not limited to, overhangs, moveable insulating walls and roofs, detached solar collectors, reflectors and piping”

As currently shown, the carport is built close to the sidewalk, which, is much further beyond the 10’-0” setback projection allowance mentioned above.

Per 6.4.5.C.1.c., for carports and garages in single-family and duplex development, the structural setback may be modified in accordance with Section 3.11.1, Design Development Option as follows:

Per 6.4.5.C.1.c.(2)., For carports, if the distance between the back of street curb and the carport is 8’-0” or less, a minimum of 1’-0” must be provided.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online.

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

Be aware this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

See below for more information on the DDO process.

4. COMMENT: 3. Per UDC Article 6.6.3.D; Accessory structures, except for accessory dwelling units, shall not exceed 12 feet in height, unless attached to a principal structure. If attached to the principal structure, maximum height permitted shall be the same as for the principal structure.

Based on provided information the carport and shed appear to exceed the allowed 12’ height. Provide the height of each structure. If either (or both) structures exceed this standard, a Board of Adjustment for Variance will be required to permit the carport and shed as shown on the plan. An option would be to connect the carport to the existing residence with a 5’ wide roof structure that can support a 20-pound live load.

Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

5. COMMENT: Regarding ALL the existing walls/fences on the property:

Per UDC 6.6.2.I, the maximum height of a wall or fence within a perimeter yard shall be 6’-0” measured from above finish grade to the top of the wall at any point along the wall run; however, the wall or fence may be higher than 6’-0”, but no higher than 10’-0”, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard.).

As currently show, one of the walls, “Cedar texture engineered treated wood siding depicts an 8’-0”’ height.

Walls/fences over 6'-0” and up to 8'-0” tall - A Design Development Option (DDO) Special Application Zoning Approval Process is required. This is an Administrative Review process with public notice.

A 7’-0” tall wall/fence must be structurally engineered by a state registered professional.

Walls/fences over 8'-0” up to 10'-0” tall - A Board of Adjustment Variance is required. This is a public hearing process with public notice.

Provide the height of all the fences/walls as measure from finish grade along multiple locations along each fence run.

If applicable, See below for more information on the DDO process.

If applicable, See below for more information on the B/A Variance process.

6. COMMENT: Per TABLE 6.3-2.A of the UDC (referenced below), the perimeter yard setback(s) along the west property line(s) are 6’-0” or 2/3 the height of the structure, WHICHEVER DISTANCE IS GREATER. Depending on the heights and location proximity to the property lines, both sheds may lie within their respective west and east setbacks. Depending on the height and how far each shed sits off the west and east property lines, there are three options:

A. 1’-0” or more or 1-0” OR Less (encroaching in setback):

(Neighbor Waiver Sample – Copy and Paste, exactly as shown, onto Site Plan):

My Name is __________________ and I am the owner of the property located at
________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.

Signature: _______________________ Date:___________________________

Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la _____________________. He revisado el plan y no tengo ninguna objeción a que estructura se encuentra o construye ____________ desde la línea de propiedad, como se muestra en el plan.

Firma: _________________________Fecha:__________________________

B. 1’-0” or more from property line and unable to obtain neighbor waiver:
If unsuccessful in the attempt to retrieve the neighbor waiver, there is a Design Development Option (or DDO) which affords an attempt to seek relief from the setback requirements. Know this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. Alert the zoning review you intend to pursue so they can create the sub-record for you ahead of your next submittal Jeffrey.cassidy@tucsonaz.gov

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

C. Less than 1’-0” from property line and unable to obtain neighbor waiver:
If unsuccessful in your attempt to retrieve the neighbor waiver, a board of adjustment variance will be required to permit the structure as shown on the site. See variance requirements below. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

7. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration .
Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . Note that multiple DDO’s can be submitted concurrently on the same application.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved.
RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit

2. Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments.

3. Resubmit ALL documents (all drawings)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
01/06/2026 PDSD Application Completeness Express REVIEW COMPLETED