Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1225-06010
Parcel: 130051030

Address:
2002 S AMALIA AV

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.2

Permit Number - TC-RES-1225-06010
Review Name: RESIDENTIAL SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/18/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/18/2025 Light Residential Building Review (OIP) Express REQUIRES RESUBMIT Requires resubmit. Please note the following:

1. Provide the BTU demand of each appliance, total demand, and total developed length from meter to the most remote appliance on the system and verify the size of the supply pipe for the connected demand (may require upgrading), G2413.3 & Table G2413.4(1).

Gas Piping Template for ease of submittal:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_template_1.pdf

You can see an example of how it's filled out here: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/gas_piping_sample_060324.pdf
12/17/2025 PDSD Application Completeness Express REVIEW COMPLETED