| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2025 | Residential Building | APPROVED | |||
| 12/22/2025 | Residential Zoning | APPROVED | |||
| 12/22/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/15/2025 | Addressing Validation | REQUIRES RESUBMIT | The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this ADU. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit. For questions: PDSD-Residential@tucsonaz.gov | ||
| 12/15/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1225-05867 Location: 2102 N SYCAMORE BL Review Date: 12/15/2025 Site Engineering Comments: 1. This property is located with the City of Tucson Alvernon Wash floodplain and will require a floodplain use permit with Elevation certificate. For this process, the proposed ADU will be given a required finished floor elevation (FFE) which will be required for floodplain compliance and must be shown/called-out on the construction plans. 2. To submit for the FPU permit, go to the sub records of permit TC-RES-1225-05867 within the TDC account associated with the permit. 3. It was found that the base flood elevation (BFE) for the proposed ADU is 2455.54 FT NAV88. This will require a minimum finished floor elevation of 2456.54 FT NAV88 4. For the submission of the FPU permit and resubmission of the Residential building permit, please submit the construction plans with a general note that states “ADU to be built to a Finished Floor Elevation of 2456.54” 5. Site Engineering will be unable to approve permit TC-RES-1225-05867 until the associated FPU permit is approved and the elevation certificate process is begun. 6. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/ Marco Contreras Engineering Associate – Site Engineering Marco.contreras@tucsonaz.gov |
||
| 12/15/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |