Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1225-05867
Parcel: 122080910

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADU v.1

Permit Number - TC-RES-1225-05867
Review Name: RESIDENTIAL ADU v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/16/2025 Residential Building APPROVED
12/22/2025 Residential Zoning APPROVED
12/22/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/15/2025 Addressing Validation REQUIRES RESUBMIT The permit and plan show to be for an Accessory Dwelling Unit (ADU) and requires to be separately addressed. Please contact Pima County Addressing at addressing@pima.gov or 520-724-9512 to assign/add the units or a new address for this ADU. Please resubmit your plans and all supporting permit documents to reflect the updated address, in addition, a change of address request will need to be submitted in order to properly update the location of this permit. For questions: PDSD-Residential@tucsonaz.gov
12/15/2025 Residential Engineering REQUIRES RESUBMIT Permit: TC-RES-1225-05867
Location: 2102 N SYCAMORE BL
Review Date: 12/15/2025
Site Engineering Comments:
1. This property is located with the City of Tucson Alvernon Wash floodplain and will require a floodplain use permit with Elevation certificate. For this process, the proposed ADU will be given a required finished floor elevation (FFE) which will be required for floodplain compliance and must be shown/called-out on the construction plans.
2. To submit for the FPU permit, go to the sub records of permit TC-RES-1225-05867 within the TDC account associated with the permit.
3. It was found that the base flood elevation (BFE) for the proposed ADU is 2455.54 FT NAV88. This will require a minimum finished floor elevation of 2456.54 FT NAV88
4. For the submission of the FPU permit and resubmission of the Residential building permit, please submit the construction plans with a general note that states “ADU to be built to a Finished Floor Elevation of 2456.54”
5. Site Engineering will be unable to approve permit TC-RES-1225-05867 until the associated FPU permit is approved and the elevation certificate process is begun.
6. Per the City of Tucson Inclusive Home Design Ordinance: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/inclusivehomedesignordinance.pdf, all new dwellings and units have a requirement to provide an “accessible route from public and common areas, including, but not limited to, a driveway or public street or sidewalk”. Draw, dimension, and label an accessible route from the driveway, sidewalk, or street to an accessible entrance. Ensure the route meets accessibility standards as articulated in Sections 402, 403, & 404 of the ADA Accessibility Standards: https://www.access-board.gov/ada/chapter/ch04/

Marco Contreras
Engineering Associate – Site Engineering
Marco.contreras@tucsonaz.gov
12/15/2025 PDSD Application Completeness Express REVIEW COMPLETED