Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1225-05860
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2026 | Residential Building - Standard | APPROVED | Approved as noted | ||
| 01/06/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/15/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1225-05860 Location: 422 N MEDFORD DR Review Date: 12/15/2025 Site Engineering Comments: 1. There exists an underground utility easement on the south boundary of the property extending 7.5’ from the property line. No permanent structure may exist within the easement without written consent from all associated utilities. 2. Show easement and correct property line dimensions/bearings on site plan, see Final Plat https://onbase.pima.gov/publicaccess/DS_NextGen_Single/etc/cq/results.html?cqid=240&OBKey__552_1=19003. If you have any questions or concerns, please contact Corey Hines Corey.Hines@TucsonAZ.gov |
||
| 12/22/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-RES-1225-05860 422 N Medford Dr., Tucson, AZ 85710 Porch Conversion to Living Space (1st Review) TRANSMITTAL DATE: 12/22/2025 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. The property dimensions shown on the site plan do not match those shown on the recorded subdivision plat for Carriage Hill No 5. Please ensure these measurements match. 2. The Carriage Hill No 5 subdivision plat ( https://gis.pima.gov/maps/detail.cfm?&parcel=133281380 Book 19, P. 9) shows a 7.5’ utility easement running along the south property line. Add and label this easement on the site plan. 3. The Carriage Hill No 5 subdivision plat shows a 16’ alley to the west of the lot. Please correct this information on the site plan. 4. Provide a letter or letters from the utility company(s) explaining that the encroachment of the proposed addition is allowed within the 7.5’ south easement. 5. List the legal description for the lot on the site plan: Carriage Hill No 5 Lot 570 6. Lot coverage is calculated using the square footage of all enclosed structures and vehicle use areas (driveway, carport – see UDC 6.4.3.B.3) and excludes porches. This sum divided by the lot’s square footage will provide the percentage of lot coverage. Please recalculate lot coverage. 7. Show the water lines on the site plan. 8. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 12/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |