Permit Number: TC-RES-1225-05753
Parcel: 12417220A

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1225-05753
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/08/2025 Site Engineering - Standard NOT REQUIRED
02/03/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
02/03/2026 Residential Building - Standard REQUIRES RESUBMIT January 20, 2026
1st Review

Intertech Architectural Interiors
Attn: Erin Hastreiter
6089 E. Grant Road


Re: DUPLEX EXPANSION
ADDITION

City of Tucson Permit Number: TC-COM-1225-05753
Stantec Project Number: 185215066
Stantec File Number: TUC-25-114

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken.

The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

Occupancy
Group Construction
Type Area
(Square feet) Occupant
Load Automatic
Fire Sprinklers Fire
Alarms
R-3 V-B 450 2 No No
Separate Permits: None.
Deferred Submittals: None.
Special Inspections: Epoxy and expansion anchors.

ARCHITECTURAL COMMENTS

General

1. Note on the cover of the drawings that special inspection is required for epoxy and expansion anchors. Also, provide City of Tucson special inspection certificate(s) with Parts A and B completed. Make sure that the owner or their legal representative signs the form.

 
STRUCTURAL COMMENTS

There are no comments.

MECHANICAL COMMENTS

There are no comments.

PLUMBING COMMENTS

There are no comments.

ELECTRICAL COMMENTS

There are no comments.


Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline.

Plans reviewed by:
Trevor Bies,
Senior Plan Reviewer
602-338-9922
trevor.bies@stantec.com
12/16/2025 Residential Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Jeffrey W. Cassidy, Planner
Planning & Development Services Department – Current Zoning Review Section

PROJECT: TC-RES-1225-05753 – Residential Building – Residential addition to exiting duplex (SFR)
1008 S MOUNTAIN AV TUCSON, AZ 85719 (R-2 Zoning)
Site Plan Review – 1st Review

TRANSMITTAL DATE: December 16, 2025

This site is in the R-2 Residence Zone (UDC 4.7.9). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Plan review for the above referenced single-family residence has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

1. COMMENT: The drawings indicate the existing residence is a duplex but, per the floor plan, there appears to be one unit (Duplex definition; UDC 11.3.7.A.1.: A building containing two dwelling units on a single or parcel). Clarify if it is the intent change what appears to be a single-family residence to a duplex. Consider updating the document labeling to ‘single family residence’ (in lieu of all the places where duplex is used).

2. COMMENT: Per UDC Table 7.4.4-1 and under the Residential Use Group and Single-Family Dwellings, 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit. Per UDC Table 7.4.6-1, a 90-degree orientation requires a 8’-6” width by 18’-0” length per stall. Demonstrate on the site plan graphically, where these two parking spaces are located, label and provide dimensions.

3. COMMENT: The site plan provided is incomplete.

a) Provide a site plan that meets the requirements show in the plot plan example at the following link:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Plan-Examples/Plot-Plan-Example

More Specifically:

1) Include vehicular use areas (driveway, parking spots), sidewalks and even ‘open’ structures like porches, shade structures, carports, sheds, fences, walls, if applicable.

Label and provide dimensions from adjacent property lines for everything that exists on the property (sheds, walls, fences and provide heights measured from above finish grade at various locations along the fence/wall) if applicable.

2) To complete missing information (legal description, subdivision name, book and page numbers, township-section and range) on the plot plan example, refer to Pima County’s website https://gis.pima.gov/maps/detail.cfm?&parcel=12417220A

3) Measure square footage of every enclosed structure on site and driveway/vehicular use area and input into lot coverage calculation table.

4) Label S Mountain Av on site plan and Zoning graphic.

5) Provide missing dimension from centerline of S Mountain Av to curb (per provided plot plan sample).

6) Provide missing dimension from curb to property line (per provided plot plan sample).

7) Draw and dimension driveway and parking spaces or areas serving as a vehicular use area.

4. COMMENT: After reviewing the property documentation history in PRO, zoning could not verify any permit documentation for the existing utility shed in the northwest corner of the parcel and additionally, is in both the west and north setbacks.

Zoning will not be able to approve the permit application until the permit information is provided. If permit documentation cannot be provided and because it appears to be over 200 sq ft in size, the utility shed may be issued under a different permit.

Per TABLE 6.3-2.A of the UDC (referenced below), the perimeter yard setback(s) along the north and west property line(s) are 6’ or 2/3 the height of the utility shed, WHICHEVER DISTANCE IS GREATER. Depending on how far the utility shed sits off each property line, three options exist:

a) 1’-0” or more or 1-0” OR Less (encroaching in setback):
Secure a neighbor setback waiver (provided below) signed and dated by the property owner(s) to the north and west:

(Neighbor Waiver Sample – Copy and Paste, exactly as shown, onto Site Plan):

My Name is __________________ and I am the owner of the property located at
________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan.

Signature: _______________________ Date:___________________________

Mi hombre es ________________ y yo soy el dueño de la propiedad ubicada en la
_____________________. He revisado el plan y no tengo ninguna objeción a que
estructura se encuentra o construye ____________ desde la línea de propiedad,
como se muestra en el plan.
Firma: _________________________Fecha: ________________________________

b) 1’-0” or more from property line and unable to obtain neighbor waiver:
Should you be unsuccessful in your attempt to retrieve the neighbor waiver there is a Design Development Option (or DDO) which affords an attempt to seek relief from the setback requirements. Know this is an extra 6-week review and the neighbors within 100’-0” are made aware of this attempt to seek relief from being in the setback. Zoning will not be able to approve the permit application until the DDO is approved. This information is linked here:

https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration#section-3

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. Alert the zoning review you intend to pursue so they can create the sub-record for you ahead of your next submittal Jeffrey.cassidy@tucsonaz.gov

https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf

See below for more information on the DDO process.

c) Less than 1’-0” from property line and unable to obtain neighbor waiver:
Should you be unsuccessful in your attempt to retrieve the neighbor waiver, a board of adjustment variance will be required to permit the utility shed as shown on the site. See variance requirements below. Zoning cannot approve this permit until the Board of Adjustment (B/A) Variance Process is completed and approved.

See below for more information on the B/A Variance process.

5. COMMENT: Per keynote 21, sheet C2.0, a separate commercial signage permit will be required to address modification of the existing signage. Contact mark.castro@tucsonaz.gov or georgia.pennington@tucsonaz.gov for any questions about setting up the permit, requirements and/or standards.

6. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other the PDSD reviewer comments.

Board of Adjustment application/requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration .
Contact for the Board of Adjustment is Mark Castro at Mark.Castro@tucsonaz.gov

DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration . Note that multiple DDO’s can be submitted concurrently on the same application.

To submit a DDO application, apply for a new sub-record under this permit at TDC Online. In order to get this specific review scheduled and if you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. Zoning cannot approve the zoning review portion of the permit until the DDO has been approved.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:

1. Corrected building permit
2. Provide a detailed response letter (clarification narrative) with your submittal that clearly shows how you have addressed all Zoning comments.
3. Resubmit ALL documents (all drawings in sheet index)

To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home

Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf

If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov

The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code
12/08/2025 PDSD Application Completeness Express REVIEW COMPLETED