Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-RES-1225-05740
Parcel: 133382490

Review Status: Requires Resubmit

Review Details: RESIDENTIAL ADD/ALT v.1

Permit Number - TC-RES-1225-05740
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/15/2025 Residential Zoning APPROVED
12/18/2025 Residential Building - Standard NOT REQUIRED
12/23/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/23/2025 Site Engineering - Standard REQUIRES RESUBMIT Permit: TC-RES-1225-05740
Location: 1951 S CALLE MESA DEL OSO
Review Date: 12/23/2025
Site Engineering Comments:
1. Per Tucson code Sec. 26.5 No development, storage of materials or equipment, or other uses shall be permitted which, acting alone or in combination with existing or future uses, create a danger or hazard to life or property.
2. Upon review of this permit and CE-VIO1025-04675 there are downstream impacts of the proposed wall, flood venting will be required.
3. Flood venting should be added every 5 feet along the wall. The opening dimensions will be 12inch wide X 6 Inch tall at grade. Please show a detail on the construction plan for a typical wall section with required flood venting. For resubmission, provide the revised construction plans.
4. A hydrology report can be obtained and submitted demonstrating alternative findings or flood venting requirements.
If you have any questions or concerns, please contact
Corey Hines
Corey.Hines@TucsonAZ.gov
12/08/2025 PDSD Application Completeness Express REVIEW COMPLETED