Permit Number: TC-RES-1224-07507
Parcel: 129062840

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1224-07507
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2025 Site Engineering NOT REQUIRED
01/07/2025 Site Landscape NOT REQUIRED
02/05/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/09/2025 Residential Building REQUIRES RESUBMIT TC-RES-1224-07507
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. The plans require sufficient detail for demonstrating minimum building code compliance for passing all progress inspections.

Note the 2018 IRC reference on the plans.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

Provide a clear and concise construction plan set. Sample drawings are available for understanding details. Sample plans at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits

SITE PLAN:

1. Show the location and size of the electrical service panel, R106.1.1. Identify the area of the building requiring repair or also provide a complete floor plan.

PLANS:

1. Show the functional name of each existing adjacent room to the area requiring repair, R106.1.1. Note all repairs or alterations with keynotes.

PLUMBING PLANS:

1. Notate alterations.

MECHANICAL PLANS:

1. Notate alterations.

ELECTRICAL PLANS:

1. Notate alterations.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
----------------------
01/28/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Ramiro Olivarez
Zoning Review Section

PROJECT: TC-RES-1224-07507
2944 E BEVERLY DR – R-1 Zoning
Fire Restoration (1st Review)

TRANSMITTAL DATE: 01/28/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9

COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed.


1. Comment: A site plan shall be included for the next review. Identify where the fire restoration work is to be completed.

The site plan should be designed to include the information as noted on the sample plot plan. See the link below for the information that is required on the plot plan. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf .

2. Comment: Clarify, will the fire restoration work be interior work or exterior work or both.
3. Comment: If additions/alterations are to be made then clearly identify and depict the work in a complete plan set.
4. Comment: Read and address the Residential Building review comments.
5. Comment: A complete review and additional comments and may be forthcoming on the next review based on the proposed use for the addition and applicable use specific standards.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Provide full plan set in the next submittal.

If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov
01/07/2025 PDSD Application Completeness Express REVIEW COMPLETED