Review Status: Requires Resubmit
Review Details: RESIDENTIAL FENCE/WALL v.2
Permit Number - TC-RES-1224-07325
Review Name: RESIDENTIAL FENCE/WALL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/16/2025 | Site Engineering | NOT REQUIRED | |||
01/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
01/03/2025 | Light Residential Building Review (OIP) | REQUIRES RESUBMIT | Permit Review TC-RES-1224-07325 (1201 W PELAAR ST TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC). 1. The fence location is outside the parcel boundary in an existing public right-of-away. Permit cannot be approved with fence blocking the right-of-way. 2. Fences over 7’ tall require a design from the foundation to the highest point sealed by an Arizona registered engineer. The fence is over 7’ tall, provide a complete design Sealed as required, R106.1. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
01/15/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-RES-1224-07325 - CE-VIO1024-04080 1201 W PELAAR ST. – R-1 8’ Tall Wood Fence Building in ROW (1st Review) TRANSMITTAL DATE: January 15, 2025 Comment: Provided a detailed comment response letter with your submittal that clearly shows how you have addressed all comments with your next submittal. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 – 9. 1. Provide a residential plot plan that meets all requirements found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Plan-Examples/Plot-Plan-Example. Clearly show the property lines and fence location. Based the aerial photo provided the fence is located within the COT right-of-way, alley. 2. Per UDC Article 6.6.2.I. The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard .) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; 3. A greater height is required through the rezoning process or the special exception land use process; or, 4. A greater height is required by a specific UDC standard. Either demonstrate that one of the 4 exceptions are met or a Design Development Option (DDO) must be approved for a wall height to exceed the allowed 6’-0”. 3. Based on aerial photos there has been an addition to the southeast corner of the single family residence (SFR) that appears sometime after 2016. Zoning was not able to find approved permit documents for this addition. Either provided stamped approved permit documents of a permit will need to be applied for and approved prior to approval of this fence permit. The unpermitted addition may be submitted as part of the fence permit as long as building plans are provided. DDO application and requirements can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Planning-Zoning-Applications/Zoning-Administration. If you have questions about the DDO application or process please contact Wyatt Berger at Wyatt.Berger@tucsonaz.gov or Georgia Pennington at Georgia.Pennington@tucsonaz.gov. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
12/31/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |