Permit Number: TC-RES-1224-07310
Parcel: 134041800

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1224-07310
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/02/2025 Residential Building REQUIRES RESUBMIT TC-RES-1224-07310
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

PLANS:

1. Show the bedroom with R310 compliant egress. The existing adjacent bedroom requires direct egress to the exterior.

SECTIONS - DETAILS:

1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38 or R-30 when extended over the wall top plate for additions under 500 SF. Clarify the ceiling/roof insulation detail showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material.

PLUMBING PLANS:

1. Show the water heater BTU rating, P2801.1.
2. Show the gas pipe sized in conformance with Table G2413.4(1).

MECHANICAL PLANS:

1. Provide heating facilities in all habitable rooms, R303.9. (Mini split, extend duct from a central HVAC or an electrical base board heater) Or show a door separating the dwelling from a proposed unheated sunroom, R303.2 Exception.

ELECTRICAL PLANS:

1. Interior alterations require the installation of smoke alarms in existing bedrooms, R314.2.2. Provide notation if the smoke alarms are existing or proposed.

If you have any questions, please contact:
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
01/17/2025 Site Engineering REQUIRES RESUBMIT TC-RES-1224-07310
417 S STAUNTON DR

Site engineering comments are as follows:
1. This project is within a regulated floodplain and requires a Floodplain Use Permit (FUP.)
Please start a new FUP at our permit application web page:
https://tdc-online.tucsonaz.gov/#/home
NOTE: A cost estimate of materials and labor from your contractor in the form of a pdf attachment will be required to complete the FUP application. Please have separate lines for cost of materials, and cost of labor. Thank you.
Ryan Insalaco – ryan.insalaco@tucsonaz.gov
01/16/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-1224-07310
417 S. Staunton Drive Tucson, AZ 85710
Arizona room and laundry room addition (1st Review)

TRANSMITTAL DATE: 1/16/2025

This site is located in the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Please update the legal description to read “Blue Ridge Estates NO 2 Lot 144”.
3. Comment: Please draw, label, and dimension the setbacks for the new Arizona room to the southeast property line.
4. Comment: Please draw, label, and dimension the half right of way to the base of wedge curb and from the base of wedge curb to the property line. Plans currently only dimension the centerline to the property line. Per construction plan I-68-012, the centerline to base of wedge curb along S Staunton Drive is 15’ and 10’ from base of wedge curb to the property line. https://maps-and-records.tucsonaz.gov/construction-plans/details/I-68-012.
5. Comment: Please add the vehicular use area (driveway) to the lot coverage calculations as it is missing.
6. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
12/18/2024 PDSD Application Completeness Express REVIEW COMPLETED