Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1224-07293
Parcel: 127101000

Address:
6129 E 2ND ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SIMPLE REVIEW v.1

Permit Number - TC-RES-1224-07293
Review Name: RESIDENTIAL SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/18/2024 Site Engineering NOT REQUIRED
12/18/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/16/2024 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1224-07293 (6129 E 2ND ST TUCSON, AZ 85711)

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans and a written response letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response letter addressing the comments below maybe be delayed until the response letter is received. For additional questions: Building_Official@tucsonaz.gov
1. Note and specify all piping material and sizes, P2609.

2. Non-metallic water line requires blue tracer line.

3. Minimum burial depth, 12'', P2603.5.

4. PRV required if PSI greater than 80

5. A minimum 1'' service pip is required when supplying more than 9.5 fixtures
12/16/2024 PDSD Application Completeness Express REVIEW COMPLETED