Permit Number: TC-RES-1224-07216
Parcel: 122170880

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - TC-RES-1224-07216
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2025 Site Engineering APPROVED
01/07/2025 Site Landscape NOT REQUIRED
01/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
01/07/2025 Residential Building REQUIRES RESUBMIT TC-RES-1224-07216
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments and building ordinances for all dwellings.

Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files.

GENERAL COMMENTS :

1. All plans submitted for a newly constructed one- or two-family dwelling after June 1, 2010, must provide gray water utilization or preparation, Ordinance #10579/11089 revised July 9, 2013. The ordinance revision now requires a gray drain line discharge from one fixture for a one-story dwelling. Show a bathing fixture drain looped 3’ beyond an exterior wall below grade before connection to the building drain when the clothes washer is not located at an exterior wall. Use the appropriate detail at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Building-Safety/Water-Energy-Conservation Gray Water Illustrations. Update the plans with a feasible option.
2. Show compliance with the Electric Vehicle Supply Equipment Ordinance adopted by the City of Tucson Ordinance #11844 on 6/22/2021. Include a 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle for charging an electric vehicle at a proposed parking space.

SECTIONS - DETAILS:

1. Attic space outside of the thermal barrier requires a ventilation calculation for showing the attic vent opening size using 1 to 150 of attic area in compliance with R806.2. Provide an attic ventilation calculation and show the location of vent openings.

ELECTRICAL PLANS:

1. Update the Riser Diagram if the guest house is connected to the proposed meter or distribution panel, NEC 225.30 and E3403.
2. Show a smoke alarm outside the bedroom doorways in the immediate vicinity, R314.3.
3. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, E3703.2 and E3901.3.
4. Provide the Electric Vehicle Supply Equipment 40 ampere 240-volt dedicated branch circuit with a NEMA 14-50R receptacle and label the circuit “EV Ready” and locate the receptacle at a parking area, N1104.2.1. Include the Electric Vehicle load entry (typically 7680 watts) in the electrical load calculations (continuous demand) like the HVAC entry, N1104.2.2.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review

Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services
01/21/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: Bobby Parsons
Zoning Section Review

PROJECT: TC-RES-1224-07216
3319 E Bellevue Street Tucson, AZ 85716
Replace SFR Demolished from Fire (1st Review)

TRANSMITTAL DATE: 1/21/2025

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.6, .9, & .10.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: The site plan should be designed to include the information as noted on the sample site plan. Please see https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf for reference.
2. Comment: Per UDC 6.4.3.C.1, “Roofed areas, open on at least one side, which provide shelter to exterior areas such as balconies, entrances, stoops, and terraces, provided they are not used for utilities, maintenance, laundry, storage, or motor vehicle parking are excluded from lot coverage calculations.” Please remove the existing shade structure and new porch from your lot coverage calculations and update the calculations.
3. Comment: Aerial imagery shows the west side of the property is utilized as the vehicular use area to the rear guest house. Please draw, label, and dimension this on your site plan and update the lot coverage calculations.
4. Comment: Please draw, label, and dimension the half right of way to the face of curb and from the face of curb to the property line along E Bellevue Street.
5. Comment: Per UDC 6.4.4.A, height is measured from design grade. Please adjust the height measurements on your plans to design grade instead of finished grade.
6. Comment: Site zoning is unable to approve this building permit until all zoning review comments have been addressed and the Design Development Option (DDO) has been approved.

Comment: The following comments are related to an application for a Design Development Option (DDO) (UDC 3.11.1):
The minimum required front street perimeter yard setback for the R-2 zone is 20’. The proposed front street perimeter yard setback for the attached carport is 6’. The proposed setback will require approval through the DDO application process. Please contact Georgia.Pennington@tucsonaz.gov or Mark.Castro@tucsonaz.gov if needed. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/planning-amp-zoning/ddo_for_setback_and_height_udc.pdf.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
01/06/2025 PDSD Application Completeness Express REVIEW COMPLETED